IT070R024Z, EMAS, optical LED horn, RED, Ø 70mm, 12- 24V AC / DC, 130dB
IT070R024Z EMAS - LED signalling beacon with acoustic signalling, red, 24 V AC / DC, 70 mm, IP65. Technical specifications, use, assembly and selection of the correct variant.
Cambio 24,43 Kč per 1 EUR. I prezzi sono indicativi, la fatturazione avviene in corone ceche.
Horns and sirens for audibly alerting operators to machine status or faults. Choose by volume, tone, supply and mounting.
IT070R024Z EMAS - LED signalling beacon with acoustic signalling, red, 24 V AC / DC, 70 mm, IP65. Technical specifications, use, assembly and selection of the correct variant.
IT070G024Z EMAS - LED signalling beacon with acoustic signalling, green, 24 V AC / DC, 70 mm, IP65. Technical specifications, use, assembly and selection of the correct variant.
IT070R240Z EMAS - LED signalling beacon with acoustic signalling, red, 48-240 V AC / DC, 70 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
IT070Y240Z EMAS - LED signalling beacon with acoustic signalling, yellow, 48-240 V AC / DC, 70 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
IT070Y024Z EMAS - LED signalling beacon with acoustic signalling, yellow, 24 V AC / DC, 70 mm, IP65. Technical specifications, use, assembly and selection of the correct variant.
IT070G240Z EMAS - LED signalling beacon with acoustic signalling, green, 48-240 V AC / DC, 70 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
I prezzi includono il contributo di riciclaggio.
The buzzer draws attention to an event that the operator does not necessarily have to watch with their eyes. In this category, there are also devices combining sound with optical LED signalling, for example, implementing EMAS IT070. The catalog name 'Buzzer' does not mean that each product only produces sound. The guide builds on the concept of states for the overall concept. Signalling beacons.
Compare the sound pressure level with the same measurement distance, frequency weighting, power supply and selected tone. The dB(A) rating is not automatically interchangeable with an unspecified dB. Even the maximum of one melody may not represent other modes. For audibility, the spectrum of noise at the operator's location also has significance.
For a specific product, have the conditions of the stated levels confirmed. The value from one measurement is not a guaranteed level on every workstation or a common parameter of all horns. Loudness also does not describe the light output: verify the visibility of the LED separately from the required directions.
First, distinguish a complete buzzer from an acoustic segment intended for a certain series of pole lights. A similar diameter does not guarantee the same capture or contacts. Installation should be chosen so that the machine cabinet does not cover the exhaust opening and the cable is not strained by pulling.
Consider a hypothetical point source with a level of 96 dB(A) at a distance of 1 m. In free space, with uniform radiation, it emits approximately 90 dB(A) at 2 m and 84 dB(A) at 4 m. This is about the model, not the range of the buzzer. Reflections, direction, coverage, and ambient noise affect the result.
Therefore, prepare a verification plan for specific workstations: record the used tone, voltage, position of the device, distance and running machines. Also test the recognition of the cause of the alarm. If the sound is used to call for assistance, add a confirmation procedure and a new call procedure upon repeated event.
No. It is important to distinguish the specific signal in the given environment. Unnecessarily long or frequent warnings complicate work and may lead to overlooking other events. Set the duration and conditions of the signalisation according to the process.
A common operating buzzer is not an automatic safety function. Sound does not indicate a stop and its silence does not remove the cause of the event. Required safety functions must be addressed in the design of the machine.
To distinguish multiple states, assess Beacons more colorful and multifunctional EMAS. Select the required mounting in Beacons accessories according to the specific series, dimensional drawing and cable routing.
I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.
Scegli quali cookie possiamo utilizzare. Puoi modificare la scelta in qualsiasi momento.
Conservano il contenuto del carrello, l'accesso e la lingua scelta e proteggono i moduli dagli abusi. Senza di essi non è possibile completare l'ordine, per questo sono utilizzati anche senza consenso.
Google Analytics ci mostra in forma aggregata il traffico e il comportamento sul sito. Così capiamo quali pagine non funzionano per gli utenti. In base a questi dati non identifichiamo nessuno.