Ultrasonic double material detection

Ultrasonic double sheet detection distinguishes missing, single and overlapping material. Choose a Pepperl+Fuchs UDC sensor according to the material, mounting distance and outputs to the control system.

Filtros
Encontrado 17 productos

6090204, SICK, ultrasonic double material sensor UD18-22C62F1, PNP/NPN, IO-Link, 20–30VDC, Connector M12/5

N.º cat.: 6090204

UD18-22C62F1 (6090204), SICK – ultrasonic double material sensor, PNP/NPN, IO-Link, 20–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.

Bajo consulta
761,15 €
sin IVA · 920,99 € con IVA

6058910, SICK, ultrasonic double material sensor UD18-22CC221, PNP, 20–30VDC, Cable 2m

N.º cat.: 6058910

UD18-22CC221 (6058910), SICK – ultrasonic double material sensor, PNP, 20–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.

Bajo consulta
826,39 €
sin IVA · 999,93 € con IVA

6058911, SICK, ultrasonic double material sensor UD18-22CC241, NPN, 20–30VDC, Cable 2m

N.º cat.: 6058911

UD18-22CC241 (6058911), SICK – ultrasonic double material sensor, NPN, 20–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.

Bajo consulta
826,39 €
sin IVA · 999,93 € con IVA

6058913, SICK, ultrasonic double material sensor UD18-22CC242, NPN, 20–30VDC, Cable 2m

N.º cat.: 6058913

UD18-22CC242 (6058913), SICK – ultrasonic double material sensor, NPN, 20–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.

Bajo consulta
843,02 €
sin IVA · 1 020,06 € con IVA

6058914, SICK, ultrasonic double material sensor UD18-22DC221, PNP, 20–30VDC, Cable 2m

N.º cat.: 6058914

UD18-22DC221 (6058914), SICK – ultrasonic double material sensor, PNP, 20–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.

Bajo consulta
1 000,37 €
sin IVA · 1 210,45 € con IVA

Double sheet sensor, UDC-18GM-400-3E1, 180198, PEPPERL+FUCHS

N.º cat.: UDC-18GM-400-3E1

Double sheet sensor, UDC-18GM-400-3E1, 180198, PEPPERL+FUCHS

Bajo consulta
813,55 €
sin IVA · 984,40 € con IVA

UDC-18GM-400-3E3, double sheet sensor, 192999, PEPPERL+FUCHS

N.º cat.: UDC-18GM-400-3E3

UDC-18GM-400-3E3, double sheet sensor, 192999, PEPPERL+FUCHS

Bajo consulta
819,54 €
sin IVA · 991,64 € con IVA

Double sheet sensor, UDC-18GMA-400-3E1, 181166, PEPPERL+FUCHS

N.º cat.: UDC-18GMA-400-3E1

Double sheet sensor, UDC-18GMA-400-3E1, 181166, PEPPERL+FUCHS

Bajo consulta
832,96 €
sin IVA · 1 007,88 € con IVA

Double sheet sensor, UDC-18GM50-400-3E1, 188641, PEPPERL+FUCHS

N.º cat.: UDC-18GM50-400-3E1

Double sheet sensor, UDC-18GM50-400-3E1, 188641, PEPPERL+FUCHS

Bajo consulta
841,97 €
sin IVA · 1 018,78 € con IVA

Double sheet sensor, UDC-18GM50-400-3E2, 188642, PEPPERL+FUCHS

N.º cat.: UDC-18GM50-400-3E2

Double sheet sensor, UDC-18GM50-400-3E2, 188642, PEPPERL+FUCHS

Bajo consulta
841,97 €
sin IVA · 1 018,78 € con IVA

Double sheet sensor, UDC-18GM50-400-3E3, 190313, PEPPERL+FUCHS

N.º cat.: UDC-18GM50-400-3E3

Double sheet sensor, UDC-18GM50-400-3E3, 190313, PEPPERL+FUCHS

Bajo consulta
841,97 €
sin IVA · 1 018,78 € con IVA

Double sheet sensor, UDC-18GM50-400-3E0, 191326, PEPPERL+FUCHS

N.º cat.: UDC-18GM50-400-3E0

Double sheet sensor, UDC-18GM50-400-3E0, 191326, PEPPERL+FUCHS

Bajo consulta
841,97 €
sin IVA · 1 018,78 € con IVA

Double sheet sensor, UDC-18GM50-255S-3E0, 206053, PEPPERL+FUCHS

N.º cat.: UDC-18GM50-255S-3E0

Double sheet sensor, UDC-18GM50-255S-3E0, 206053, PEPPERL+FUCHS

Bajo consulta
876,36 €
sin IVA · 1 060,39 € con IVA

Double sheet sensor, UDC-18GM50-255S-3E1, 206054, PEPPERL+FUCHS

N.º cat.: UDC-18GM50-255S-3E1

Double sheet sensor, UDC-18GM50-255S-3E1, 206054, PEPPERL+FUCHS

Bajo consulta
876,36 €
sin IVA · 1 060,39 € con IVA

Double sheet sensor, UDC-18GM50-255S-3E3, 206055, PEPPERL+FUCHS

N.º cat.: UDC-18GM50-255S-3E3

Double sheet sensor, UDC-18GM50-255S-3E3, 206055, PEPPERL+FUCHS

Bajo consulta
876,36 €
sin IVA · 1 060,39 € con IVA

Double material sensor, UDC-30GM-085-3E3, 193141, PEPPERL+FUCHS

N.º cat.: UDC-30GM-085-3E3

Double material sensor, UDC-30GM-085-3E3, 193141, PEPPERL+FUCHS

Bajo consulta
1 223,30 €
sin IVA · 1 480,19 € con IVA

Los precios incluyen la tasa de reciclaje.

Double sheet detection during material feeding

An ultrasonic double material sensor monitors the passage of sound between the emitter and receiver. The evaluation distinguishes the state without material, one layer and overlapping layers. It is used for feeding sheets into printing, packaging and processing machines, where missing or multiple feeding needs to be detected.

Ultrasonic double sheet detection Pepperl+Fuchs UDC-18GM-400-3E1
Example of a split assembly for sheet monitoring: Pepperl+Fuchs UDC-18GM-400-3E1.

How to choose a sensor for paper, film or sheet metal

  • Material and layers: state the type of material, thickness or grammage and the required state when overlapping.
  • Mounting: compare the distance between emitter and receiver, the position of the sheet and the installation angle according to the drawing of the specific model.
  • Rychlost linky: the response and output pulse length must correspond to the passage time of the sheet and the PLC input.
  • Electrical design: verify the supply, PNP/NPN outputs, NO/NC function and connection.

Pepperl+Fuchs UDC series in this category

The range includes versions UDC-18GM, UDC-18GMA, UDC-18GM50 and UDC-30GM. You can compare, for example, UDC-18GM-400-3E1 and UDC-30GM-085-3E3. Permitted materials and mounting conditions are assessed for the complete order code.

Is a double sheet sensor suitable for measuring thickness?

Its main task is to distinguish material states during feeding. For continuous thickness measurement, a measuring system with the corresponding specification must be chosen.

Technical document: Pepperl+Fuchs datasheet UDC-18GM-400-3E1.

Selection questions

What data are needed to choose double sheet detection?

Prepare a sample of the material, its thickness or grammage, feed speed and the available space for both heads. Compare the mounting distance, installation angle and the method of evaluating the individual states.

What should the sensor report for a missing or overlapping sheet?

Require distinction between the state without material, a single sheet and multiple feeding. When wiring, assign the outputs according to the manual of the exact UDC type and verify that the PLC captures the pulse at the highest line speed.

Selection and technical consultation

For selection or replacement, send the complete order code and a description of the application. TECHNOLINE technical support will help compare the required version.

Related: Label and splice detection · Ultrasonic through-beam barriers · All special ultrasonic sensors · Sensor Cables and Connectors.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.