Telefon +420 774 723 123 Kosár · 0 · üres

Ultrasonic double material detection

Ultrasonic double sheet detection distinguishes missing, single and overlapping material. Choose a Pepperl+Fuchs UDC sensor according to the material, mounting distance and outputs to the control system.

Szűrők
Találatok 17 termék

Double sheet sensor, UDC-18GM-400-3E1, 180198, PEPPERL+FUCHS

Kat. szám: UDC-18GM-400-3E1

Double sheet sensor, UDC-18GM-400-3E1, 180198, PEPPERL+FUCHS

Érdeklődjön
813,55 €
ÁFA nélkül · 984,40 € ÁFÁ-val

UDC-18GM-400-3E3, double sheet sensor, 192999, PEPPERL+FUCHS

Kat. szám: UDC-18GM-400-3E3

UDC-18GM-400-3E3, double sheet sensor, 192999, PEPPERL+FUCHS

Érdeklődjön
819,54 €
ÁFA nélkül · 991,64 € ÁFÁ-val

Double sheet sensor, UDC-18GMA-400-3E1, 181166, PEPPERL+FUCHS

Kat. szám: UDC-18GMA-400-3E1

Double sheet sensor, UDC-18GMA-400-3E1, 181166, PEPPERL+FUCHS

Érdeklődjön
832,96 €
ÁFA nélkül · 1 007,88 € ÁFÁ-val

Double sheet sensor, UDC-18GM50-400-3E1, 188641, PEPPERL+FUCHS

Kat. szám: UDC-18GM50-400-3E1

Double sheet sensor, UDC-18GM50-400-3E1, 188641, PEPPERL+FUCHS

Érdeklődjön
841,97 €
ÁFA nélkül · 1 018,78 € ÁFÁ-val

Double sheet sensor, UDC-18GM50-400-3E2, 188642, PEPPERL+FUCHS

Kat. szám: UDC-18GM50-400-3E2

Double sheet sensor, UDC-18GM50-400-3E2, 188642, PEPPERL+FUCHS

Érdeklődjön
841,97 €
ÁFA nélkül · 1 018,78 € ÁFÁ-val

Double sheet sensor, UDC-18GM50-400-3E3, 190313, PEPPERL+FUCHS

Kat. szám: UDC-18GM50-400-3E3

Double sheet sensor, UDC-18GM50-400-3E3, 190313, PEPPERL+FUCHS

Érdeklődjön
841,97 €
ÁFA nélkül · 1 018,78 € ÁFÁ-val

Double sheet sensor, UDC-18GM50-400-3E0, 191326, PEPPERL+FUCHS

Kat. szám: UDC-18GM50-400-3E0

Double sheet sensor, UDC-18GM50-400-3E0, 191326, PEPPERL+FUCHS

Érdeklődjön
841,97 €
ÁFA nélkül · 1 018,78 € ÁFÁ-val

Double sheet sensor, UDC-18GM50-255S-3E0, 206053, PEPPERL+FUCHS

Kat. szám: UDC-18GM50-255S-3E0

Double sheet sensor, UDC-18GM50-255S-3E0, 206053, PEPPERL+FUCHS

Érdeklődjön
876,36 €
ÁFA nélkül · 1 060,39 € ÁFÁ-val

Double sheet sensor, UDC-18GM50-255S-3E1, 206054, PEPPERL+FUCHS

Kat. szám: UDC-18GM50-255S-3E1

Double sheet sensor, UDC-18GM50-255S-3E1, 206054, PEPPERL+FUCHS

Érdeklődjön
876,36 €
ÁFA nélkül · 1 060,39 € ÁFÁ-val

Double sheet sensor, UDC-18GM50-255S-3E3, 206055, PEPPERL+FUCHS

Kat. szám: UDC-18GM50-255S-3E3

Double sheet sensor, UDC-18GM50-255S-3E3, 206055, PEPPERL+FUCHS

Érdeklődjön
876,36 €
ÁFA nélkül · 1 060,39 € ÁFÁ-val

Az árak tartalmazzák az újrahasznosítási díjat.

Double sheet detection during material feeding

An ultrasonic double material sensor monitors the passage of sound between the emitter and receiver. The evaluation distinguishes the state without material, one layer and overlapping layers. It is used for feeding sheets into printing, packaging and processing machines, where missing or multiple feeding needs to be detected.

Ultrasonic double sheet detection Pepperl+Fuchs UDC-18GM-400-3E1
Example of a split assembly for sheet monitoring: Pepperl+Fuchs UDC-18GM-400-3E1.

How to choose a sensor for paper, film or sheet metal

  • Material and layers: state the type of material, thickness or grammage and the required state when overlapping.
  • Mounting: compare the distance between emitter and receiver, the position of the sheet and the installation angle according to the drawing of the specific model.
  • Rychlost linky: the response and output pulse length must correspond to the passage time of the sheet and the PLC input.
  • Electrical design: verify the supply, PNP/NPN outputs, NO/NC function and connection.

Pepperl+Fuchs UDC series in this category

The range includes versions UDC-18GM, UDC-18GMA, UDC-18GM50 and UDC-30GM. You can compare, for example, UDC-18GM-400-3E1 and UDC-30GM-085-3E3. Permitted materials and mounting conditions are assessed for the complete order code.

Is a double sheet sensor suitable for measuring thickness?

Its main task is to distinguish material states during feeding. For continuous thickness measurement, a measuring system with the corresponding specification must be chosen.

Technical document: Pepperl+Fuchs datasheet UDC-18GM-400-3E1.

Selection questions

What data are needed to choose double sheet detection?

Prepare a sample of the material, its thickness or grammage, feed speed and the available space for both heads. Compare the mounting distance, installation angle and the method of evaluating the individual states.

What should the sensor report for a missing or overlapping sheet?

Require distinction between the state without material, a single sheet and multiple feeding. When wiring, assign the outputs according to the manual of the exact UDC type and verify that the PLC captures the pulse at the highest line speed.

Selection and technical consultation

For selection or replacement, send the complete order code and a description of the application. TECHNOLINE technical support will help compare the required version.

Related: Label and splice detection · Ultrasonic through-beam barriers · All special ultrasonic sensors · Sensor Cables and Connectors.

Sütik ezen a weboldalon

A technikai sütikre a kosár és a rendelés működéséhez van szükség — ezeket mindig használjuk. Az analitikai sütik megmutatják, mely oldalakat keresik az emberek és hol akadnak el, és segítenek javítani a webáruházat. Ezeket csak akkor használjuk, ha engedélyezi. Bővebben: adatkezelési tájékoztatóban.