6041661, SICK, ultrasonic level sensor UP56-211112, 30–250mm, PNP, 9–30VDC, Connector M12/5
UP56-211112 (6041661), SICK – ultrasonic level sensor, 30–250mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
Tipo de cambio 24,43 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
Ultrasonic level sensors measure the distance from the transducer to the surface of the medium without direct contact with the level. This group includes devices explicitly intended by the manufacturer for level measurement in tanks and silos. Always assess suitability for liquids or bulk solids according to the specific medium and version.
UP56-211112 (6041661), SICK – ultrasonic level sensor, 30–250mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211114 (6041664), SICK – ultrasonic level sensor, 30–250mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211115 (6073255), SICK – ultrasonic level sensor, 30–250mm, IO-Link, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211118 (6041658), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211128 (6048700), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211148 (6048942), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211156 (6050441), SICK – ultrasonic level sensor, 30–250mm, 4–20mA, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211156S01 (6086572), SICK – ultrasonic level sensor, 30–250mm, 4–20mA, 9–30VDC. Parameters, wiring and manufacturer documentation.
UP56-2111A8 (6054782), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212112 (6041662), SICK – ultrasonic level sensor, 85–350mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212114 (6041665), SICK – ultrasonic level sensor, 85–350mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212115 (6073256), SICK – ultrasonic level sensor, 85–350mm, IO-Link, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212118 (6041659), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212128 (6048701), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212148 (6048943), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212156 (6049945), SICK – ultrasonic level sensor, 85–350mm, 4–20mA, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-2121A8 (6054783), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213112 (6041663), SICK – ultrasonic level sensor, 200–1300mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213114 (6041666), SICK – ultrasonic level sensor, 200–1300mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213115 (6073257), SICK – ultrasonic level sensor, 200–1300mm, IO-Link, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213118 (6041660), SICK – ultrasonic level sensor, 200–1300mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213128 (6048702), SICK – ultrasonic level sensor, 200–1300mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-2131A8 (6054784), SICK – ultrasonic level sensor, 200–1300mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-214112 (6041695), SICK – ultrasonic level sensor, 350–3400mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-214114 (6041694), SICK – ultrasonic level sensor, 350–3400mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
Los precios incluyen la tasa de reciclaje.
Ultrasonic level sensors measure the distance from the transducer to the surface of the medium without direct contact with the level. This group includes devices explicitly intended by the manufacturer for level measurement in tanks and silos. Always assess suitability for liquids or bulk solids according to the specific medium and version.
The BUS M30E2 series is explicitly intended by the manufacturer for non-contact level measurement in tanks. Assess the G 1 process connection and the design of the active face together with the medium, pressure and required sealing method. The maximum range may not be identical to the recommended working range; the datasheet of the specific variant is decisive.
View BALLUFF BUS005U · Use of the M30E2 series for level according to the manufacturer.
A level meter evaluates the return of the ultrasonic echo. The level height is determined from the measured distance and the specified geometry. For continuous measurement, verify the corresponding analogue or digital output; a switching output signals that a set limit has been reached. Conversion to volume requires knowledge of the vessel shape.
With an empty tank, the surface must still be within range, and when full it must remain outside the blind zone. Allow a reserve for waves. Choose the sensor position with regard to walls, stiffeners, agitators and the filling stream, which can create unwanted reflections or obstruct the measuring path.
Foam can attenuate the ultrasonic signal; a changing environment affects sound propagation. Therefore also test filling, emptying and agitation. For bulk solids, take into account the uneven surface and the pouring cone. The degree of protection of the housing alone does not confirm chemical resistance or usability in a pressure vessel.
In some applications yes, if it corresponds to the documentation and operating conditions. However, the mere ability to sense a liquid surface does not make an ordinary sensor a process level meter. Assess the design and the manufacturer's explicit intended use together.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: VEGA ultrasonic level meter technical documentation · VEGA documentation on ultrasonic level measurement.
The level height is the difference between the known distance of the face from the reference bottom and the currently measured distance to the surface. Conversion to volume requires the vessel geometry; the highest level must remain outside the blind zone.
No. For example, BUS005U has two PNP switching outputs for limit states. For continuous measurement, compare the analogue variants BUS005W, BUS005Y, BUS0085 or BUS0086 and their specific range.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.