PR12-TM10DPO – Through-beam light barrier receiver

PR12-TM10DPO (LANBAO) is a through-beam light barrier receiver in a Ø M12. design. The emitter and receiver face each other; the sensor switches when an object interrupts the beam between them. Of all optical principles, it offers the longest range and highest reliability regardless of the colour and surface of the object.

Key features

  • Sensing distance 10 m.
  • PNP output, NO contact – normally open – connects to a PLC digital input or a relay coil.
  • Supply 10–30 V DC.
  • Connection: cable 2 m PVC.
  • Operating temperature up to 15 / +55 °C.

Technical specifications PR12-TM10DPO

Order code PR12-TM10DPO
Manufacturer LANBAO
Size / housing Ø M12
Housing material metal (nickel/copper)
Sensing distance (Sn) 10 m
Output type PNP
Contact function NO – normally open
Supply voltage 10–30 V DC
Connection cable 2 m PVC
Operating temperature up to 15 / +55 °C
Light source Infrared light (880nm)
Beam direction Straight
Max. load current 200mA
HS code (TARIC) 85365019
Country of origin CN

Wiring of PR12-TM10DPO by wire colours

Wire Colour Wiring
1 brown (BN) + supply (L+), 10–30 V DC
2 blue (BU) − supply (M / 0 V)
3 black (BK) PNP output, NO – switches on detection; switches the positive pole – for a sinking-type PLC input

The colour coding complies with IEC 60947-5-2. Always compare the actual pin and wire assignment with the diagram in the sensor datasheet (Downloads tab).

Wiring diagram of PR12-TM10DPO: brown plus, black output, blue minus

Three-wire cable wiring according to IEC 60947-5-2.

The same sensor with a different connection

The cable version is cheaper, but replacing the sensor requires pulling the entire cable. The connector variant can be replaced in a minute and is suitable where there is no time for downtime.

Typical applications

  • detection over long distances across a conveyor or hall
  • monitoring the passage of pallets, cartons and crates
  • counting objects regardless of their colour and gloss
  • detection of dark, matt and transparent objects
  • monitoring entry into the machine area and vehicle entrances

How to choose and what to watch out for

  • PNP output (switches plus) matches the standard PLC digital inputs used in Europe. For NPN-type inputs, choose the corresponding variant with the same sensing distance.
  • NO contact (normally open): the output is activated when an object is detected. If you need the opposite logic, an NC variant is available.
  • Cable outlet: the cheaper variant, but replacing the sensor requires pulling the entire cable. If you need quick replacement, choose a model with a connector (suffix -E1 for M8, -E2 for M12).
  • Operating temperature up to 15 / +55 °C applies to continuous operation. Short-term exceedance shortens service life and may permanently degrade the sensing distance.

PNP or NPN – and what happens if you mix them up

PNP switches the positive pole, so it sends plus to the PLC input. It is the European standard and matches standard digital inputs. NPN switches minus and is used mainly in Asian equipment. If mixed up, the sensor either does not switch at all or reports a permanently active state — it usually will not be damaged, but it will not work.

This model has a PNPoutput. If you need NPN, a variant with the same sensing distance is available — contact us and we will recommend the code.

NO or NC – and why it is not just a matter of convenience

NO (normally open) is an output that is active on detection. NC (normally closed) is active at rest and opens on detection. The difference is a safety one: with NC, a broken wire causes the same reaction as a detection, so the fault shows up immediately. With NO, a broken cable remains unnoticed until someone tries to switch.

This model has the contact NO – normally open.

Similar models in the same series

Frequently asked questions

Does PR12-TM10DPO have a PNP or NPN output?

PR12-TM10DPO has a PNP output with an NO contact – normally open. It therefore matches the standard PLC digital inputs used in Europe.

What is the sensing distance of PR12-TM10DPO?

The sensing distance (Sn) is 10 m.

How is PR12-TM10DPO connected?

PR12-TM10DPO is supplied with the connection: cable 2 m PVC. The cable is part of the sensor; the other end is free for connection to a terminal block.

How is PR12-TM10DPO wired by wire colours?

Brown wire to supply plus, blue to minus, and black is the signal output going to the PLC input or relay coil. The coding complies with IEC 60947-5-2.

Do I need to buy the emitter and receiver separately?

Yes. A through-beam barrier consists of two parts — the emitter and receiver have separate order codes, and both must be supplied with power and mounted facing each other on the beam axis.

A detailed datasheet with a dimension drawing and wiring diagram can be found in the tab Downloads.

We supply PR12-TM10DPO from the Czech Republic with an invoice and technical support. Not sure which one to choose? Send us your application parameters and we will recommend a suitable model.

Do you have a sensor from another manufacturer on your machine – SICK, IFM, Balluff, Omron or Pepperl+Fuchs? Send us its order code and we will cross-reference it to the matching LANBAO model.

Technical parameters

Objednací kódPR12-TM10DPO
VýrobceLanbao
TypeThrough-beam - SET
Range10m
ConnectionCable 2m
Power supply10-30VDC
OutputPNP
ContactNO
Emission directionStraight
Sensor typeReceiver and emitter
DiameterM12
MaterialMetal

Downloads

Ask about this product

Ask us about technical parameters, compatibility with your equipment, availability or a price for larger quantities. It helps if you tell us what application you need the product for — if it does not fit, we will recommend a more suitable type.

Kód k opsání. Pokud ho nepřečtete, klikněte na Načíst nový kód.
The question relates to product PR12-TM10DPO

By sending you agree to the processing of the data provided for the purpose of handling your question. We do not pass the data on to third parties.

Related products

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.