TLS0004, TECHNOLINE, retro-reflective laser photoelectric sensor, polarised reflection from reflector, 10m, PNP, NO and NC, cable 2 m
- Regular price excl. VAT
- 200,94 €
- incl. VAT
- 243,14 €
- Our price excl. VAT
- 140,66 €
- incl. VAT 21 %
- 170,20 €
- You save
- 60,28 € excl. VAT
Description
TLS0004, TECHNOLINE, retro-reflective laser photoelectric sensor, polarised reflection from reflector, 10m, PNP, NO and NC, cable 2 m
TLS0004 is a retro-reflective laser photoelectric sensor marks TECHNOLINE designed for precise non-contact detection in industrial automation.
Design of this variant: polarised reflection from reflector, working distance 10m, output PNP, function NO and NC and connection cable 2 m.
Laser detection principle
The emitter and receiver are in one housing and a retroreflector is placed opposite the sensor. An object in the detection path interrupts the returning beam.
Typical applications
A retro-reflective laser sensor works with a reflector / retroreflector placed opposite the sensor. The laser beam returns from the reflector back to the sensor, and an object between the sensor and the reflector interrupts the beam. It is suitable for longer distances, conveyor lines, packaging lines and precise detection of object passage.
Typical applications include checking part presence, passage detection, positioning, edge checking, product counting and sensing objects on conveyors, packaging machines and assembly lines.
Technical specifications
| Order code | TLS0004 |
|---|---|
| Manufacturer | TECHNOLINE |
| Product type | retro-reflective laser photoelectric sensor |
| Principle / function | polarised reflection from reflector |
| Sensing distance / range | 10m |
| Output type | PNP |
| Output function | NO and NC |
| Supply | 10–30 V DC |
| Connection | cable 2 m |
| Current consumption | 20 mA |
| Degree of protection | IP67 |
| Light source | Red laser (650nm) Class 1 |
| Beam width | 10 mm |
| Operating temperature | -10°C to +50°C |
| Material | plastic |
Mounting and adjustment
Mount the sensor firmly and without mechanical stress. Set the laser beam to the required detection point, reflector or opposite receiver according to the principle of the specific variant. After mechanical adjustment, verify stable switching across the entire working range and also in extreme operating states.
When mounting, take into account contamination of the optics, vibration, changes in the surface of the sensed object and possible scattering of ambient light. For precision applications, we recommend verifying the operating reserve directly on the machine after installation.
How to choose the right variant
Compare the sensing principle, working distance, PNP/NPN output type, NO/NC function, supply, connector or cable, dimensions, degree of protection and properties of the detected object. When replacing an existing sensor, it is safest to work from the exact order code and electrical wiring of the original device.
Related categories
FAQ
What kind of sensor is TLS0004?
TLS0004 is a retro-reflective laser photoelectric sensor made by TECHNOLINE. The exact technical design is given in the parameters table.
What is the working range of TLS0004?
The source data state a working range of 10m.
What output does TLS0004 have?
According to the export, the output is PNP and the function is NO and NC.
Can this laser sensor be connected to a PLC?
Yes, if the voltage and type of PLC input match the electrical output of the sensor. Before wiring, compare the PNP/NPN version, NO/NC function, supply and common potential.
Why use a laser photoelectric sensor?
A laser source produces a narrow light spot and is suitable where more precise localisation of the object or detection of a smaller target is required than with a conventional wide light beam.
What affects the reliability of laser detection?
The surface and colour of the target, angle of incidence, distance, contamination of the optics, ambient conditions and accuracy of mechanical adjustment.
How to mount a laser sensor correctly?
Fix the sensor without mechanical stress, set the optical axis relative to the target or reflector, and after mounting verify stable switching even in extreme operating states.
How to choose the right replacement?
Compare the order code, sensing principle, working distance, PNP/NPN output, NO/NC function, supply, connector or cable, dimensions and degree of protection.
Where can I find other laser and optoelectronic sensors?
More variants are in the category optoelectronic sensors.
Is laser safety a concern with a laser sensor?
Yes. Observe the laser class data and safety instructions of the specific product. Do not look directly into the laser beam and follow the documentation of the model during installation.
Which reflector should be used with a retro-reflective laser sensor?
Use a compatible retroreflector recommended for the sensor. You will find other variants in the category retro-reflective light barriers with reflector.
Technical parameters
| Objednací kód | TLS0004 |
|---|---|
| Výrobce | TECHNOLINE |
| Type | Retro-reflective (reflector) |
| Range | 10m |
| Connection | Cable 2m |
| Power supply | 10-30VDC |
| Output | PNP |
| Contact | NO and NC |
Downloads
Ask about this product
Related products
PSE-PM10DPRL, LANBAO, retro-reflective laser photoelectric sensor with reflector, 10m, PNP, NO and NC, cable 2m, 10-30VDC
PSE-PM10DPRL
53,31 €
excl. VAT · 64,51 € incl. VAT
PSE-PM10DPRL-E3, LANBAO, retro-reflective laser photoelectric sensor with reflector, 10m, PNP, NO and NC, M8/4-pin, 5m
PSE-PM10DPRL-E3
53,31 €
excl. VAT · 64,51 € incl. VAT
PSE-PM5DPRL, LANBAO, retro-reflective laser photoelectric sensor with reflector, 5m, PNP, NO and NC, cable 2m
PSE-PM5DPRL
53,31 €
excl. VAT · 64,51 € incl. VAT
PSE-PM5DPRL-E3, LANBAO, retro-reflective laser photoelectric sensor with reflector, 5m, PNP, NO and NC, M8/4-pin
PSE-PM5DPRL-E3
53,31 €
excl. VAT · 64,51 € incl. VAT
PSE-PM2DPRL, LANBAO, retro-reflective laser photoelectric sensor with reflector, 2m, PNP, NO and NC, cable 2m
PSE-PM2DPRL
53,31 €
excl. VAT · 64,51 € incl. VAT