Three-position switches 60 °

EMAS three-position 1–0–2 cam switches with 60°, e.g. for selecting local–0–automatic. Choose by number of poles and current.

Filtri
Trovati 29 prodotti
−3 % IL NOSTRO CONSIGLIO DISPONIBILE

PSA010KD234S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 2, current 10A

Cod. cat.: PSA010KD234S

PSA010KD234S EMAS - cam switch 1-0-2, 400V AC, 10 A, IP54. Technical specifications, use, assembly and selection of the correct variant.

Disponibile 5 pz e oltre
12,98 € 13,38 €
IVA esclusa · 15,70 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

PSA016KD234S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 2, current 16A

Cod. cat.: PSA016KD234S

PSA016KD234S EMAS - cam switch 1-0-2, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Disponibile 5 pz e oltre
13,74 €
IVA esclusa · 16,63 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

PSA025KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 25A

Cod. cat.: PSA025KD134S

PSA025KD134S EMAS - cam switch 1-0-2, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.

Disponibile 5 pz e oltre
15,18 €
IVA esclusa · 18,37 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

PSA025KD434S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 4, current 25A

Cod. cat.: PSA025KD434S

PSA025KD434S EMAS - cam switch 1-0-2, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.

Disponibile 3 ks
24,69 €
IVA esclusa · 29,87 € IVA inclusa
−3 % IL NOSTRO CONSIGLIO DISPONIBILE

PSA025KD334S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 3, current 25A

Cod. cat.: PSA025KD334S

PSA025KD334S EMAS - cam switch 1-0-2, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.

Disponibile 5 pz e oltre
25,96 € 26,76 €
IVA esclusa · 31,41 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

PSA032KD434S, EMAS, standard switch

Cod. cat.: PSA032KD434S

PSA032KD434S EMAS - cam switch 1-0-2, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.

Disponibile 2 ks
31,00 €
IVA esclusa · 37,51 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA010KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 10A

Cod. cat.: PSA010KD134S

PSA010KD134S EMAS - cam switch 1-0-2, 400V AC, 10 A, IP54. Technical specifications, use, assembly and selection of the correct variant.

Su richiesta
9,19 €
IVA esclusa · 11,12 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA016KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 16A

Cod. cat.: PSA016KD134S

PSA016KD134S EMAS - cam switch 1-0-2, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
9,51 €
IVA esclusa · 11,50 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA020KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 20A

Cod. cat.: PSA020KD134S

PSA020KD134S EMAS - cam switch 1-0-2, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
10,23 €
IVA esclusa · 12,37 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA020KD234S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 2, current 20A

Cod. cat.: PSA020KD234S

PSA020KD234S EMAS - cam switch 1-0-2, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
15,18 €
IVA esclusa · 18,37 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA032KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 32A

Cod. cat.: PSA032KD134S

PSA032KD134S EMAS - cam switch 1-0-2, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
16,58 €
IVA esclusa · 20,06 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA010KD334S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 3, current 10A

Cod. cat.: PSA010KD334S

PSA010KD334S EMAS - cam switch 1-0-2, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
17,66 €
IVA esclusa · 21,37 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA016KD334S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 3, current 16A

Cod. cat.: PSA016KD334S

PSA016KD334S EMAS - cam switch 1-0-2, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
17,93 €
IVA esclusa · 21,69 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA025KD234S, EMAS, switch standard 1-0-2, angle 60 °, number of poles 2, current 25A

Cod. cat.: PSA025KD234S

PSA025KD234S EMAS - cam switch 1-0-2, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
18,33 €
IVA esclusa · 22,18 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA020KD334S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 3, current 20A

Cod. cat.: PSA020KD334S

PSA020KD334S EMAS - cam switch 1-0-2, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
19,73 €
IVA esclusa · 23,87 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA032KD234S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 2, current 32A

Cod. cat.: PSA032KD234S

PSA032KD234S EMAS - cam switch 1-0-2, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
24,64 €
IVA esclusa · 29,82 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA040KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 40A

Cod. cat.: PSA040KD134S

PSA040KD134S EMAS - cam switch 1-0-2, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
25,72 €
IVA esclusa · 31,13 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA040KD234S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 2, current 40A

Cod. cat.: PSA040KD234S

PSA040KD234S EMAS - cam switch 1-0-2, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
30,63 €
IVA esclusa · 37,07 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA050KD134S, EMAS, switch standard 1-0-2, angle 60 °, number of poles 1, current 50A

Cod. cat.: PSA050KD134S

PSA050KD134S EMAS - cam switch 1-0-2, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
33,11 €
IVA esclusa · 40,06 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA063KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 63A

Cod. cat.: PSA063KD134S

PSA063KD134S EMAS - cam switch 1-0-2, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
34,87 €
IVA esclusa · 42,19 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA032KD334S, EMAS, switch standard 1-0-2, angle 60 °, number of poles 3, current 32A

Cod. cat.: PSA032KD334S

PSA032KD334S EMAS - cam switch 1-0-2, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
34,87 €
IVA esclusa · 42,19 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA050KD234S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 2, current 50A

Cod. cat.: PSA050KD234S

PSA050KD234S EMAS - cam switch 1-0-2, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
38,07 €
IVA esclusa · 46,06 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA080KD134S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 1, current 80A

Cod. cat.: PSA080KD134S

PSA080KD134S EMAS - cam switch 1-0-2, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
38,75 €
IVA esclusa · 46,89 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA040KD334S, EMAS, switch standard 1-0-2, angle 60 °, number of poles 3, current 40A

Cod. cat.: PSA040KD334S

PSA040KD334S EMAS - cam switch 1-0-2, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
39,91 €
IVA esclusa · 48,29 € IVA inclusa
IL NOSTRO CONSIGLIO

PSA063KD234S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 2, current 63A

Cod. cat.: PSA063KD234S

PSA063KD234S EMAS - cam switch 1-0-2, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Su richiesta
40,09 €
IVA esclusa · 48,51 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Three-position switches 60 °

A three-position switch with the marking 1–0–2 offers two options separated by the central position. It is suitable as a default solution where the operator must explicitly select the neutral state besides two modes. The electrical meaning of the center must correspond to the contact program and the function of the entire device. Zero on the label is not itself confirmation of safe disconnection.

One extra position is not another pole

The offer includes EMAS PSA010KD134S, PSA016KD234S and PSA025KD434S. PSA010KD134S Manufacturer presents One pole, position 1-0-2, angle 60 °, forehead 48 × 48 mm and Ie 10 A in AC21A. The device has three marked positions, yet it is not three-pole. The required number of switched paths is therefore determined separately.

Compared to two-position switches 60 ° The main difference is the available central option, not automatically higher load capacity. Even the number of visible contacts cannot be simply converted to the number of poles without a diagram. The contact program may include bindings that are not visible on the front side.

How to specify the centre position

Describe which paths in the center are interrupted and which functions should remain available. For the process mode 'off', for example, signalization or diagnostics may remain active. This is not the same as disconnecting the input for maintenance. If the switch has to handle disconnection, you need a specifically specified applicability of the concrete device and the design of the corresponding circuit.

Besides the fixed positions, check the passage through the center. The assignment must determine whether a conflict of commands can occur when switching from 1 to 2 and how it might be evaluated. The actual contact closure, the moment of disconnection and engagement, and any auxiliary paths are determined by the production diagram. The angle on the label does not replace the time sequence.

Model example Local -0-Automation

Consider your own logical panel assignment. Position 1 requires the local mode, the center interrupts both mode requests, and position 2 asks for automation. The table of required signals M/A has therefore the states 1/0, 0/0, and 0/1. The combination 1/1 is not permissible. This is not the actual contact table PSA010KD134S; it is the basis on which the designer selects the appropriate program.

We will then select the request so that the input to the automation does not automatically start the movement. The mode selection differs from the command to start. When crossing zero, the control must unequivocally determine whether the unfinished request is being cancelled and whether new confirmation is necessary. A mechanical switch cannot resolve this follow-up logic without the design of other parts.

Electrical load and installation

For each looped path, determine the type of load and working conditions. Two circuits controlled by one handle do not necessarily have to have the same voltage or contact resistance; the suitability of such use must be determined. The current from the catalog name is not a universal motor value. For control inputs, also consider the actual small looped current.

On the panel, the center must be clearly identifiable and the marking must agree with the mechanism setting. Check the mounting dimensions and cable space both before and after closing the doors. Comparing multiple options offers a branch. step cam switches; general selection procedure Vacuum cleanersElectrical installation is performed by a competent person.

Frequently asked questions

Does 1-0-2 automatically mean engine reversing?

No. Revision requires appropriate program and motor switching parameters. A similar label does not demonstrate such function.

Can I use the center as a service disconnect?

Only if this function explicitly meets the specific performance and is correctly incorporated into the device. Normal cancellation of command is not proof of a hopeless state.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.