EMA Pressure Sensors

EMA pressure sensors with analogue output for liquids and gases. Choose by pressure range, medium, process connection and output.

Sottocategorie

Filtri
Trovati 41 prodotti
IL NOSTRO CONSIGLIO DISPONIBILE

US0004, adapter for pressure sensors, EMA ELECTRONIC

Cod. cat.: US0004

US0004, adapter G1/4" to G1/2" for pressure sensors, EMA ELECTRONIC

Disponibile 5 pz e oltre
7,74 €
IVA esclusa · 9,36 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

US0005, adapter for pressure sensors, EMA ELECTRONIC

Cod. cat.: US0005

US0005, adapter G1/4" to G1/4" for pressure sensors, EMA ELECTRONIC

Disponibile 5 pz e oltre
7,74 €
IVA esclusa · 9,36 € IVA inclusa
−40 % IL NOSTRO CONSIGLIO DISPONIBILE

Smart pressure sensor, thread G1/4 in., for pressure 2 bar, PA1101

Cod. cat.: PA1101

smart programmable pressure sensor with user pressure setting, pressure range: 0-2 bar, offers 4 pressure units: bar, MPa, psi and kg/cm3, simple and practical design without the need for…

Disponibile 1 ks
134,13 € 223,54 €
IVA esclusa · 162,29 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/4", for pressure 2 bar, output 4-20mA, PB1101

Cod. cat.: PB1101

Pressure sensor, thread G1/4", for pressure 2 bar, output 4-20mA, PB1101

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/4", for pressure 2 bar, output 0-10V, PB1102

Cod. cat.: PB1102

Pressure sensor, thread G1/4", for pressure 2 bar, output 0-10V, PB1102

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/4", for pressure 5 bar, output 0-10V, PB1104

Cod. cat.: PB1104

Pressure sensor, thread G1/4", for pressure 5 bar, output 0-10V, PB1104

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/4", for pressure 10 bar, output 0-10V, PB1106

Cod. cat.: PB1106

Pressure sensor, thread G1/4", for pressure 10 bar, output 0-10V, PB1106

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/4", for pressure 20 bar, output 0-10V, PB1108

Cod. cat.: PB1108

Pressure sensor, thread G1/4", for pressure 20 bar, output 0-10V, PB1108

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/4", for pressure 50 bar, output 0-10V, PB1110

Cod. cat.: PB1110

Pressure sensor, thread G1/4", for pressure 50 bar, output 0-10V, PB1110

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/4", for pressure 5 bar, output 4-20mA, PB1103

Cod. cat.: PB1103

Pressure sensor, thread G1/4", for pressure 5 bar, output 4-20mA, PB1103

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/2", for pressure 2 bar, output 4-20mA, 2PB1101

Cod. cat.: 2PB1101

Pressure sensor, thread G1/2", for pressure 2 bar, output 4-20mA, 2PB1101

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/2", for pressure 2 bar, output 0-10V, 2PB1102

Cod. cat.: 2PB1102

Pressure sensor, thread G1/2", for pressure 2 bar, output 0-10V, 2PB1102

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/2", for pressure 5 bar, output 0-10V, 2PB1104

Cod. cat.: 2PB1104

Pressure sensor, thread G1/2", for pressure 5 bar, output 0-10V, 2PB1104

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/2", for pressure 10 bar, output 0-10V, 2PB1106

Cod. cat.: 2PB1106

Pressure sensor, thread G1/2", for pressure 10 bar, output 0-10V, 2PB1106

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/2", for pressure 20 bar, output 0-10V, 2PB1108

Cod. cat.: 2PB1108

Pressure sensor, thread G1/2", for pressure 20 bar, output 0-10V, 2PB1108

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/2", for pressure 50 bar, output 0-10V, 2PB1110

Cod. cat.: 2PB1110

Pressure sensor, thread G1/2", for pressure 50 bar, output 0-10V, 2PB1110

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

Pressure sensor, thread G1/2", for pressure 5 bar, output 4-20mA, 2PB1103

Cod. cat.: 2PB1103

Pressure sensor, thread G1/2", for pressure 5 bar, output 4-20mA, 2PB1103

Su richiesta
121,39 €
IVA esclusa · 146,88 € IVA inclusa
IL NOSTRO CONSIGLIO

2PB1107, pressure sensor, Ema Elecronic

Cod. cat.: 2PB1107

pressure sensor; thread: G1/2"; for pressure 20 bar; output: 4-20mA; Ema Elecronic

Su richiesta
121,40 €
IVA esclusa · 146,89 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

EMA pressure sensors

Choose an EMA pressure sensor as part of a specific measuring point. The normal pressure, short-term peaks, properties of the medium and the signal required by the control input are important. When replacing an older device, therefore, do not rely on an identical housing appearance. Record the complete code, connection designation and evaluation method; it is precisely this combination that determines what the new device must meet.

Scope of range and related parts

The range here includes PB and 2PB analogue transmitters and accessories US0004 and US0005. To select a specific transmitter, continue to Simple pressure sensors. Mechanical connections are addressed by pressure Accessories. Split the order into the measuring device, mechanical parts and electrical connection so that a verified counterpart is not missing during mounting.

WIKA distinguishes between measuring range, overload and burst pressure. The burst limit is not a permissible working pressure. In the specification, therefore, also state events during valve closure, pump start-up and depressurisation, not just the value monitored during steady operation. The specific limit for EMA must be determined by the corresponding product sheet.

The range affects the usefulness of the reading

An excessively wide range can be a disadvantage if the significant deviation is specified as a percentage of its full-scale value. Conversely, an excessively narrow range may not cover actual operation. Therefore base the decision on the required resolution of changes and documented load limits. The error in bar cannot be calculated from the expression "accuracy in percent" without stating the basis.

Author's example: percentages have different bases

Let us compare two model devices with ranges of 0 to 10 bar and 0 to 100 bar. For the example, assign both a deviation of ±0.5 % of full scale. The first corresponds to ±0.05 bar, the second to ±0.50 bar. At a measured pressure of 2 bar, this is 2.5 % and 25 % of the value currently measured, respectively.

These deviations are not parameters of EMA products. The calculation only shows the significance of the selected range. The actual uncertainty may include other influences, and when comparing catalogues it is necessary to distinguish linearity, repeatability, temperature influence and the method of determining the resulting deviation.

Medium and mounting

Check all wetted materials, not just the visible metal of the connection. WIKA also includes seals among wetted parts; their suitability may be decisive for a specific liquid. The resistance of the housing to the environment is assessed separately from the chemical and thermal suitability of the process connection.

Before mounting, record the tapping location, device orientation and the required service space. Make the connection after depressurising and securing the process. After installation, verify tightness and compare the reading with a reference in several operating states. If short peaks appear, first determine their origin; smoothing the display alone does not prove that the mechanical stress on the measuring point has disappeared.

For maintenance, keep the set input range, units and the acceptance report. Future replacement can then be based on documented requirements, not on memory of the last display value.

FAQ

Does the same brand mean an automatic replacement?

No. Compare the exact range, pressure reference system, output, connection and operating conditions.

Does an adapter change the measuring range of the sensor?

A mechanical adapter alone does not convert the range. It enables a specific connection, whose suitability and limit conditions must be verified separately.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.