Compound beacons

Assembled EMAS 50 mm signal beacons with IP65 protection, ready for mounting. Choose by number of colours, light mode and supply.

Filtri
Trovati 32 prodotti
IL NOSTRO CONSIGLIO

IK53F024XM03E-RGYF, EMAS, three-colour LED signal tower / beacon 50 mm, colours red + green + yellow, flashing, 24 V AC / DC, IP65

Cod. cat.: IK53F024XM03E-RGYF

IK53F024XM03E-RGYF EMAS - three-colour LED signal tower / beacon 50 mm; colours red + green + yellow; 24 V AC / DC; IP65.

Su richiesta
71,45 €
IVA esclusa · 86,46 € IVA inclusa
IL NOSTRO CONSIGLIO

IK53L220XM03E-RGY, EMAS, three-colour LED signal tower / beacon 50 mm, colours red + green + yellow, permanent light, 220 V AC, IP65

Cod. cat.: IK53L220XM03E-RGY

IK53L220XM03E-RGY EMAS - three-colour LED signal tower / beacon 50 mm; colours red + green + yellow; 220 V AC; IP65.

Su richiesta
71,50 €
IVA esclusa · 86,51 € IVA inclusa
IL NOSTRO CONSIGLIO

IK53F220XM03E-RGYF, EMAS, three-colour LED signal tower / beacon 50 mm, color red + green + yellow, flashing, 220 V AC, IP65

Cod. cat.: IK53F220XM03E-RGYF

IK53F220XM03E-RGYF EMAS - three-colour LED signal tower / beacon 50 mm; colours red + green + yellow; 220 V AC; IP65.

Su richiesta
73,58 €
IVA esclusa · 89,03 € IVA inclusa
IL NOSTRO CONSIGLIO

IK54L024XM03E-RGYBL, EMAS, four-colour LED signal tower / beacon 50 mm, colours red + green + yellow + blue, permanent light, 24 V AC / DC, IP65

Cod. cat.: IK54L024XM03E-RGYBL

IK54L024XM03E-RGYBL EMAS - four-colour LED signal tower / beacon 50 mm; colours red + green + yellow + blue; 24 V AC / DC; IP65.

Su richiesta
91,03 €
IVA esclusa · 110,15 € IVA inclusa
IL NOSTRO CONSIGLIO

IK54F024XM03E-RGYBLF, EMAS, four- colour LED signal tower / beacon 50 mm, color red + green + yellow + blue, flashing, 24 V AC / DC, IP65

Cod. cat.: IK54F024XM03E-RGYBLF

IK54F024XM03E-RGYBLF EMAS - four-colour LED signal tower / beacon 50 mm; colours red + green + yellow + blue; 24 V AC / DC; IP65.

Su richiesta
94,54 €
IVA esclusa · 114,40 € IVA inclusa
IL NOSTRO CONSIGLIO

IK54L220XM03E-RGYBL, EMAS, four- colour LED signal tower / beacon 50 mm, colours red + green + yellow + blue, permanent light, 220 V AC, IP65

Cod. cat.: IK54L220XM03E-RGYBL

IK54L220XM03E-RGYBL EMAS - four-colour LED signal tower / beacon 50 mm; colours red + green + yellow + blue; 220 V AC; IP65. Precision technical specifications, use and selection of variants.

Su richiesta
108,79 €
IVA esclusa · 131,63 € IVA inclusa
IL NOSTRO CONSIGLIO

IK54F220XM03E-RGYBLF, EMAS, four- colour LED signal tower / beacon 50 mm, color red + green + yellow + blue, flashing, 220 V AC, IP65

Cod. cat.: IK54F220XM03E-RGYBLF

IK54F220XM03E-RGYBLF EMAS - four-colour LED signal tower / beacon 50 mm; colours red + green + yellow + blue; 220 V AC; IP65. Precision technical specifications, use and selection of variants.

Su richiesta
111,61 €
IVA esclusa · 135,04 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Compound beacons

Select finished lamps according to the exact assembly code. The catalog offers, for example, red IK51L024XM03E-R and other color constructions. For a new machine, first set the required signal and voltage. When replacing an existing product, also compare the screw, dimensions, and connections to avoid unplanned modifications to the device during replacement.

EMAS IK production overview also lists IK51F024XM03E as a flashing 50mm version for 24V AC / DC.

Light function selection

Continuous and intermittent signals can be displayed according to what the service needs to know. For a long-term state, a calm display may be appropriate; for a response request, consider the intermittent mode. Each option should be verified in the documentation of the selected code. It cannot be assumed that a finished lamp allows switching modes if its connection does not specify such an option.

Pay special attention to the colored ends. Assign the meaning of color according to the workplace rules and compare the textual description with the delivery label. It is easiest to catch a replacement of a similarly looking product before securing it on the machine. For assessing a series of options, refer to Economic beacons - diameter 50mm EMAS (IP65).

What to check before connection

Verify the power data on the product and in its documentation. Do not transfer the AC/DC notation to a construction with a different voltage. Prepare a connection diagram, identify the terminals, and access the location where the circuit can be disconnected during maintenance. The construction must not hang on the connecting cable.

Before drilling the pin, check the flatness of the base and the intended orientation. After installation, inspect the closure of the column, the cable passage, and areas exposed to dirt. Covering should only be applied to the specified configuration and installation conditions. Additional brackets, other cable inputs, or modifications may require new verification.

Model example: warning for filled tray

The model equipment sends a red signal when parts need to be removed. The designer checks IK51L024XM03E-R as a candidate for the intended power circuit. Place the column in the worker's view and set the conditions for turning on and off. Then test the response when filling, removing parts, and refilling. The test includes normal working lighting; simply lighting the table does not prove the correct placement.

If a sound requirement is subsequently created, the modified assembly shall be reassessed. EMAS Catalogue in the case of IP65, it excludes variants with a horn.

Frequently asked questions

Do I order all installation parts with beacon?

Check the delivery range for a specific item. The required external holder or machine cabling may not be included.

Where do we proceed to damage one segment?

Category Individual modules and accessoriesDetermine the replacement part according to the full identification of the original design and retain the documentation of the repair.

Does IP65 mean security function?

No. The beacon displays the operational status and is not a safety device. The green or the off alarm itself does not show that it is allowed to manipulate inside the machine.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.