Valves

3/2, 5/2 and 5/3 pneumatic directional valves with electrical, pneumatic or manual actuation. Choose by function, rest position, port and coil voltage.

Filtros
Encontrado 174 productos

VUVS-L25-P53E-MD-G14-F8-1C1, Festo, solenoid valve, 575539

N.º cat.: VUVS-L25-P53E-MD-G14-F8-1C1

VUVS-L25-P53E-MD-G14-F8-1C1, Festo, solenoid valve, 575539. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
122,44 €
sin IVA · 148,15 € con IVA

SY5420-5YO-C8F-Q, SMC, solenoid valve

N.º cat.: SY5420-5YO-C8F-Q

SY5420-5YO-C8F-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Bajo consulta
123,26 €
sin IVA · 149,14 € con IVA

VUVS-L20-B52-D-Q8-F7-1C1, solenoid valve, 576516, Festo

N.º cat.: VUVS-L20-B52-D-Q8-F7-1C1

solenoid valve, 576516, Festo

Bajo consulta
125,72 €
sin IVA · 152,12 € con IVA

SY9320-5YO-C10F-Q, solenoid pilot-operated valve, SMC

N.º cat.: SY9320-5YO-C10F-Q

SY9320-5YO-C10F-Q, solenoid pilot-operated valve, SMC

Bajo consulta
127,35 €
sin IVA · 154,10 € con IVA

VNB403B-F25A, SMC, air-operated valve

N.º cat.: VNB403B-F25A

VNB403B-F25A, SMC, air-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
130,22 €
sin IVA · 157,57 € con IVA

MHE2-MS1H-5/2-QS-4, Festo, solenoid valve, 525117

N.º cat.: MHE2-MS1H-5/2-QS-4

MHE2-MS1H-5/2-QS-4, Festo, solenoid valve, 525117. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
133,08 €
sin IVA · 161,03 € con IVA

SY3220-5GU-M5-X10-Q, SMC, solenoid 5/2 valve, bistable, 24V DC

N.º cat.: SY3220-5GU-M5-X10-Q

SY3220-5GU-M5-X10-Q, SMC, solenoid 5/2 valve, bistable, 24V DC. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
133,25 €
sin IVA · 161,23 € con IVA

VH411-F04-L, SMC, manually operated valve

N.º cat.: VH411-F04-L

VH411-F04-L SMC – manually operated valve. When selecting, verify the connection, size and other parameters of the specific variant.

Bajo consulta
135,75 €
sin IVA · 164,25 € con IVA

SY5220-5DZ-C6-Q, SMC, solenoid pilot-operated valve

N.º cat.: SY5220-5DZ-C6-Q

SY5220-5DZ-C6-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
141,27 €
sin IVA · 170,94 € con IVA

CPE14-M1CH-5J-1/8, Festo, 550239, solenoid valve

N.º cat.: CPE14-M1CH-5J-1/8

CPE14-M1CH-5J-1/8, Festo, 550239, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
145,37 €
sin IVA · 175,89 € con IVA

R-3-1/4-B, Festo, roller lever valve, 8985

N.º cat.: R-3-1/4-B

R-3-1/4-B, Festo, roller lever valve, 8985. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Bajo consulta
146,19 €
sin IVA · 176,89 € con IVA

EAV2000-F02-5YO-Q, SMC, two-stage soft-start valve, for Europe

N.º cat.: EAV2000-F02-5YO-Q

EAV2000-F02-5YO-Q, SMC, two-stage soft-start valve, for Europe. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Bajo consulta
146,19 €
sin IVA · 176,89 € con IVA

MFH-3-1/8, Festo, solenoid valve, 7802

N.º cat.: MFH-3-1/8

MFH-3-1/8, Festo, solenoid valve, 7802. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
146,60 €
sin IVA · 177,38 € con IVA

CPE14-M1BH-5J-1/8, Festo, 196939, solenoid valve

N.º cat.: CPE14-M1BH-5J-1/8

CPE14-M1BH-5J-1/8 Festo – 196939, solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Bajo consulta
149,87 €
sin IVA · 181,34 € con IVA

EAV3000-F03-5YO-Q, two-stage soft-start valve, for Europe, SMC

N.º cat.: EAV3000-F03-5YO-Q

EAV3000-F03-5YO-Q, two-stage soft-start valve, for Europe, SMC

Bajo consulta
158,47 €
sin IVA · 191,75 € con IVA

EAV3000-F03-5YZ-Q, SMC, two-stage soft-start valve, for Europe

N.º cat.: EAV3000-F03-5YZ-Q

EAV3000-F03-5YZ-Q, SMC, two-stage soft-start valve, for Europe. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Bajo consulta
158,47 €
sin IVA · 191,75 € con IVA

EAV4000-F04-5YO-Q, two-stage soft-start valve, for Europe, SMC

N.º cat.: EAV4000-F04-5YO-Q

EAV4000-F04-5YO-Q, two-stage soft-start valve, for Europe, SMC

Bajo consulta
175,25 €
sin IVA · 212,06 € con IVA

VFS2300-5FZ-Q, SMC, solenoid pilot-operated valve

N.º cat.: VFS2300-5FZ-Q

VFS2300-5FZ-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
176,89 €
sin IVA · 214,04 € con IVA

CPE24-M1H-5/3G-3/8, solenoid valve, 170265, Festo

N.º cat.: CPE24-M1H-5/3G-3/8

solenoid valve; voltage? 24VDC; 170265; Festo

Bajo consulta
179,76 €
sin IVA · 217,51 € con IVA

CPE24-M1H-5/3E-3/8, solenoid valve, 170267, Festo

N.º cat.: CPE24-M1H-5/3E-3/8

solenoid valve; voltage: 24VDC; 170267; Festo

Bajo consulta
179,76 €
sin IVA · 217,51 € con IVA

AV3000-F03S-5KOZ-A, SMC, two-stage soft-start valve

N.º cat.: AV3000-F03S-5KOZ-A

AV3000-F03S-5KOZ-A, SMC, two-stage soft-start valve. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.

Bajo consulta
186,31 €
sin IVA · 225,43 € con IVA

VNB703B-F50A, SMC, air-operated 2/2 valve, for compressed air, water, oil and vacuum

N.º cat.: VNB703B-F50A

VNB703B-F50A, SMC, air-operated 2/2 valve, for compressed air, water, oil and vacuum. A solenoid valve electrically controls the direction of compressed air flow.

Bajo consulta
309,34 €
sin IVA · 374,30 € con IVA

JMFH-5-1/2-S, Festo, solenoid valve, 35548

N.º cat.: JMFH-5-1/2-S

JMFH-5-1/2-S Festo – solenoid valve, 35548. When selecting, verify the connection, size and other parameters of the specific variant.

Bajo consulta
420,50 €
sin IVA · 508,80 € con IVA

VNC711A-50A-5DZ-Q, SMC, solenoid valve

N.º cat.: VNC711A-50A-5DZ-Q

VNC711A-50A-5DZ-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Bajo consulta
584,26 €
sin IVA · 706,96 € con IVA

Los precios incluyen la tasa de reciclaje.

Pneumatic directional valves

A directional valve controls the connection of the supply, working paths and exhaust according to its functional symbol. For selection, you need the required state of the actuator and the behaviour when the command and energy change. The number of ways alone does not describe the rest or centre position.

Selection data Valves

Step What to document
Identification symbol, number of ways and positions
Operating requirements pilot pressure and electrical actuation
Acceptance circuit switching and exhaust

The range here includes TE3V/TE4V, SMC SY, VQ, VX and VDW series as well as Festo valves. For a service replacement, start with the function of the original circuit and the full part code. Similar-looking bodies may represent different circuits.

Number of positions and rest state

At TECHNOLINE, they represent TE3V310-10-NC-DC24V-LD a TE3V310-10-NO-DC24V-LD two rest variants 3/2. NC means the supply path to the working output is closed in the home state, NO means it is open. When selecting, therefore, draw the required media path with the electrical command disconnected.

TE4V310-10-NC-DC24V-LD is 5/2, while TE4V330C-10-NC-DC24V-LD is a 5/3 with a closed centre position. NC or NO alone is not a complete description of all channels of a 5-way valve. For example, Festo VUVS-L25-P53E-MD-G14-F8-1C1 uses an exhaust centre. Read the specific arrangement from the symbol; do not create a replacement simply by counting the coils.

Pilot pressure and medium are separate criteria

Festo datasheet 8042543 explicitly states pilot operation and internal pilot air supply. For your own selection sheet, therefore, record the pressure of the working branch and the requirements of the pilot stage separately. For an external pilot, verify its separate supply according to the diagram. Electrical voltage alone does not confirm that the pneumatic conditions for switching are met.

For 2-way valves, the medium and the pressure differential are further distinguished. SMC manual VQ20/30 requires a minimum differential of 0.01 MPa for opening. Catalogue VX21/22/23 separates the highest system pressure from the highest working pressure differential. Record both input values in the comparison; a high pressure upstream of the valve alone is not enough.

Model calculation: pressure upstream of the valve is insufficient

For our own example, let us assume pressures measured against the same reference: 0.43 MPa upstream of the valve and 0.425 MPa downstream. The difference is Δp = 0.43 − 0.425 = 0.005 MPa, i.e. 5 kPa. With our own design requirement of at least 20 kPa, this model situation does not comply, even though there is significant overpressure at the inlet.

If, in the second model situation, the outlet pressure drops to 0.40 MPa, the difference increases to 30 kPa. This only meets the considered pressure differential condition. The example does not determine the flow rate, opening time or suitability of a specific valve. The actual values must be determined during the working sequence, not taken from the compressor setting.

Mounting and targeted diagnostics

Before disconnecting, ensure a de-energised and depressurised state. The VQ20/30 manual requires a functional test and leak check after mounting. For this series, it also points out that a locked manual override can change the response to switching off the electrical command. Therefore, include the manual override position in the check before start-up.

As our own diagnostic procedure, record the command, voltage and pressure conditions at the same time. Compare a standalone cycle with simultaneous operation of other consumers. If the problem occurs only in the assembly, add to the check Plates for terminals and the connected line. Look up the electrical variant via Accessories, always according to the full code.

FAQ

Is the 5/2 valve a replacement for 5/3?

This cannot be assumed without changing the required function. Also include the behaviour of the third position in the comparison and verify whether the working sequence actually needs it.

Can the permitted medium be determined from the series designation?

Only in combination with the exact variant and its documentation. For orientation in the whole range, use Pneumatic valves; inclusion of a product alone does not confirm its suitability for water, oil or vacuum.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.