TEAC2010-02, filter regulator, TECHNOLINE
filter regulator with lubricator; flow rate: 500Nl/min; pressure: 0-1MPa; connection: G1/4 inch; TECHNOLINE
Tipo de cambio 24,43 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
Complete filter–regulator–lubricator units for actuators that require lubricated air. Choose by port and flow.
filter regulator with lubricator; flow rate: 500Nl/min; pressure: 0-1MPa; connection: G1/4 inch; TECHNOLINE
filter regulator with lubricator; flow rate: 1700Nl/min; pressure: 0-1MPa; connection: G3/8 inch; TECHNOLINE
AW30-F03H-D, filter / pressure regulator, SMC
AW20-F01CH-A, SMC, filter / pressure regulator. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
AW30-F03DH-D, SMC, filter / pressure regulator. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
AW40-N06H-2Z-D, filter / pressure regulator, SMC
AC30A-F03D-A, SMC, modular unit. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
25A-AW40-N06-NZ-D, filter / pressure regulator, SMC
Los precios incluyen la tasa de reciclaje.
A filter, regulator and lubricator assembly combines air preparation, pressure control and any oil addition. Each function has its own selection criteria. The use of a lubricator must correspond to the consumer; it is not an automatic addition to every modern pneumatic branch.
| Step | What to document |
|---|---|
| Identification | filtration, regulation and oil requirement |
| Operating requirements | simultaneous consumption of the whole branch |
| Acceptance | pressure and function of the individual modules |
Design an assembly with lubrication only according to the requirement of the connected equipment. For each consumer, we recommend writing down whether it requires oil supply, what pressure it needs and when it consumes air. These data form the basis for branch distribution and module selection. The mere presence of three functions does not yet address all the requirements of the whole machine.
The separate SMC manual AC-A shows that AC30A-A connects AW30-A with AL30-A. For the offered AC30A-F03D-A the code D corresponds to an N.O. float drain, which is open without pressure; it does not designate generation D. The last A belongs to the generation designation. The order table also distinguishes the version without a pressure gauge and variants with a gauge.
The range includes TEAC2010-02 and TEAC3010-03 from TECHNOLINE, AC30A-F03D-A and several AW versions. Choose each item according to its own description and full code. For separate lubrication, see the category Lubricators; modules are connected using Connecting accessories. Explicitly mark the presence of the required components in the assembly design.
Filtration, pressure adjustment and oil supply are different functions. Our own design rule is simple: write the requirement of each consumption point into the diagram and check which stages precede it. For two different branches, create two rows of specification. This shows which requirements can be met by the common supply and which must be addressed directly in the specific branch.
The AC-A manual warns that branching and rising lines downstream of the lubricator can disrupt oil transport. The arrangement of the modules is therefore not just a question of space. For AL-D, the manufacturer also states that the numerical scale of the knob expresses the setting position, not the amount of oil delivered. Setting the dose requires checking the actual behaviour under consumption.
The following numbers are our own model, not the flow parameters of the assembly. Let us assume two branches with consumption of 180 and 120 l/min, both relative to the same reference conditions. With simultaneous consumption, the requirement for the common supply is 180 + 120 = 300 l/min. For a preliminary specification, we choose our own reserve of 25 %: 300 × 1.25 = 375 l/min. This reserve is not a manufacturer's recommendation or a guarantee of correct sizing.
If, in the model, only the first branch needs lubrication, we assess its lubricator for the corresponding consumption of 180 l/min, while the common supply is assessed for simultaneity. To verify a specific product, we must add the pressure operating point and the characteristic. The average consumption per shift would not be the same input for this purpose as the instantaneous simultaneity.
For acceptance, we recommend creating your own checklist: full codes, module order, flow direction, access to bowls and available measuring points. Carry out service after depressurising according to the manuals of the parts used. After assembly, verify tightness and function with a repeatable cycle. Record the initial state so that other operators can compare the results.
For ordering, use the documented composition of the specific item. For a combination, verify the list of parts; inclusion in the category alone does not replace this check.
Compare the original and new simultaneity of consumption, the pressures at the same points and the requirements of the added branch. Then verify each changed section of the design separately.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.