On / Off Switches 60 °

EMAS ON/OFF 0–1 cam switches with 60° switching angle. Choose by current and number of poles.

Filtros
Encontrado 36 productos
NUESTRO CONSEJO

PSA080AK131S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 1, current 80A

N.º cat.: PSA080AK131S

PSA080AK131S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
26,81 €
sin IVA · 32,44 € con IVA
NUESTRO CONSEJO

PSA050AK231S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 2, current 50A

N.º cat.: PSA050AK231S

PSA050AK231S EMAS - main cam switch 0-1, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
33,05 €
sin IVA · 39,99 € con IVA
NUESTRO CONSEJO

PSA063AK231S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 2, current 63A

N.º cat.: PSA063AK231S

PSA063AK231S EMAS - main cam switch 0-1, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
35,03 €
sin IVA · 42,39 € con IVA
NUESTRO CONSEJO

PSA080AK231S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 2, current 80A

N.º cat.: PSA080AK231S

PSA080AK231S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
37,64 €
sin IVA · 45,55 € con IVA
NUESTRO CONSEJO

PSA050AK331S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 3, current 50A

N.º cat.: PSA050AK331S

PSA050AK331S EMAS - main cam switch 0-1, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
41,50 €
sin IVA · 50,21 € con IVA
NUESTRO CONSEJO

PSA063AK331S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 3, current 63A

N.º cat.: PSA063AK331S

PSA063AK331S EMAS - main cam switch 0-1, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
44,65 €
sin IVA · 54,03 € con IVA
NUESTRO CONSEJO

PSA080AK331S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 3, current 80A

N.º cat.: PSA080AK331S

PSA080AK331S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
51,72 €
sin IVA · 62,58 € con IVA

Los precios incluyen la tasa de reciclaje.

On / Off Switches 60 °

Splice On/Off switches at 60° for a clear switch between off and on operational states. For a two-way switch, the specification changes: do not choose A or B, but determine which electrical paths to close in position 1 and open in position 0. The required number of poles depends on the circuit, not on the number of these positions.

Specific offer of the PSA series

For example, TECHNOLINE presents EMAS PSA010AK131S, PSA016AK131S and PSA020AK131S. Manufacturer for PSA016AK131S confirms one pole path, marking 0-1, angle 60 ° and forehead 48 × 48 mm. His Ie 16 A is given in category AC21A. This model therefore represents a specific single-pole design, not a universal solution of each supply.

What one handle really has to control

Before selecting, determine all paths that change state together. Current mechanical control does not mean that currents from different poles simply add up to a single allowed value. Each path has its load, and the entire device has its operational conditions. For a combination of several functions, also verify the actual contact program.

Position 0 is the operational state indicator, not proof of suitability for insulation. If the project requires a main disconnection function, handle it explicitly according to the documentation. Even transitioning to a branch On / Off Safety switches 90 ° is not an automatic solution to such a requirement without checking the parameters.

Model example of resistance load

To explain the current, choose two ideal resistive loads, each with 600 W at 230 V. Each draws approximately 600/230 = 2.61 A. The total power is 1,200 W. If considering a common path carrying both loads, it draws approximately 5.22 A; a single path for one load still carries only 2.61 A. The specific circuit structure determines this.

This specific example does not determine the wiring of fuses or the recommended number of poles. It calculates an ideal steady-state load, not a possible startup event or device heating. Results cannot be transferred to a motor of the same power. For a motor, specify the starting value and usage conditions; a simple ratio of watts and volts does not create it.

Selection of design and assembly space

When swapping, keep function 0–1 but compare the full code, usage category, voltage, and mechanical arrangement. A larger current model does not necessarily have the same depth or mounting. Add the panel part dimensions and access to connection points with a diagram.

For separate installation choose the corresponding box and other accessoriesThe enclosure of the entire assembly depends on the installation of the controller and cable inputs. For a switch, compare the marked position with the actual contact state and the machine documentation. Installing on mains voltage is not a task for trial installation based on a similar photo; it should be done by a professional.

Frequently asked questions

Is the two-position switch automatically two-pole?

No. Two 0 and 1 positions determine the grip states. The number of poles is a separate electrical figure.

Is a higher current enough if the type of appliance changes?

Not always. Another load may require a different category or special switching conditions, even if it has a smaller steady-state consumption.

When to select a switch instead of a switch?

When the actuator has to choose between multiple functions, not just allow one. The distribution of programs and basic dimensioning rules describes the overview Vacuum cleaners.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.