Level Sensors

Endress+Hauser, ifm and other level sensors for continuous measurement and point level monitoring – ultrasonic, radar, capacitive and hydrostatic. Choose by medium, range and output.

Filtros
Encontrado 14 productos
−10 % EN STOCK

Ultrasonic sensor, 3RG6012-3AH00, AN, Siemens

N.º cat.: 3RG6012-3AH00

Ultrasonic sensor, 3RG6012-3AH00, SIEMENS

En stock 1 ks
378,79 € 420,88 €
sin IVA · 458,34 € con IVA
−10 % EN STOCK

Liquiphant FTL51-1KVK0/0, vibrating level limit switch Endress Hauser

N.º cat.: FTL51-1KVK0/0

Liquiphant FTL51-1KVK0/0, vibrating level limit switch Endress Hauser

En stock 1 ks
457,03 € 507,80 €
sin IVA · 553,01 € con IVA
−10 % EN STOCK

Time-of-Flight ultrasonic measurement Prosonic FMU41-ARB2A2, Endress Hauser

N.º cat.: FMU41-ARB2A2

Time-of-Flight ultrasonic measurement Prosonic FMU41-ARB2A2, Endress Hauser

En stock 2 ks
574,94 € 638,81 €
sin IVA · 695,68 € con IVA
−10 % EN STOCK

Time-of-Flight ultrasonic measurement Prosonic FMU41-1RB1A4, Endress Hauser

N.º cat.: FMU41-1RB1A4

Time-of-Flight ultrasonic measurement Prosonic FMU41-1RB1A4, Endress Hauser

En stock 1 ks
633,90 € 704,32 €
sin IVA · 767,02 € con IVA
−10 % EN STOCK

Time-of-Flight ultrasonic measurement Prosonic FMU41-JNB2C3, Endress Hauser

N.º cat.: FMU41-JNB2C3

Time-of-Flight ultrasonic measurement Prosonic FMU41-JNB2C3, Endress Hauser

En stock 4 ks
987,64 € 1 097,36 €
sin IVA · 1 195,04 € con IVA
NUESTRO CONSEJO

7ML5610-0BD20, capacitive level probe, Siemens

N.º cat.: 7ML5610-0BD20

measuring range 0 to 0.25bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C, protection IP68, PUR cable 3m; PVC wire insulation

Bajo consulta
227,65 €
sin IVA · 275,46 € con IVA
NUESTRO CONSEJO

Level sensor LR7000 IFM, LR0000B-BR34AQPKG/US

N.º cat.: LR7000

electrical design DC PNP, supply voltage 18 – 30 VDC, 2 switching outputs: 2x NO/NC programmable, medium temperature 0 +80°C, protection IP67, max. tank pressure -1 to 4bar, process connection G3/4…

Bajo consulta
342,68 €
sin IVA · 414,64 € con IVA
NUESTRO CONSEJO

Level sensor LR8000 IFM, LR0000B-BR34ASPKG/US

N.º cat.: LR8000

electrical design DC PNP, supply voltage 18 – 30 VDC, 4 switching outputs: 4x NO/NC programmable, medium temperature 0 +80°C, protection IP67, max. tank pressure -1 to 4bar, process connection G3/4…

Bajo consulta
397,50 €
sin IVA · 480,98 € con IVA
NUESTRO CONSEJO

Level sensor LR3000 IFM, LR0000B-BR34AMPKG/US

N.º cat.: LR3000

electrical design DC PNP, supply voltage 18 – 30 VDC, 2 independent output signals: OUT1 NO / NC, OUT2 analogue 4-20mA / 0-10V, medium temperature 0 +80°C, protection IP67 max. tank pressure -1 to…

Bajo consulta
405,57 €
sin IVA · 490,74 € con IVA
NUESTRO CONSEJO

Level probe PS3208 IFM, SUBMERSIBLE 0.25BAR 3M CABLE

N.º cat.: PS3208

measuring range 0 to 0.25bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C, protection IP68, PUR cable 3m; PVC wire insulation

Bajo consulta
437,30 €
sin IVA · 529,13 € con IVA
NUESTRO CONSEJO

Level probe PS3407 IFM, SUBMERSIBLE 0.6BAR 10M CABLE

N.º cat.: PS3407

measuring range 0 to 0.6bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C, protection IP68, PUR cable 10m; PVC wire insulation

Bajo consulta
481,60 €
sin IVA · 582,73 € con IVA
NUESTRO CONSEJO

Level probe PS3417 IFM, SUBMERSIBLE 1BAR 12M CABLE

N.º cat.: PS3417

measuring range 0 to 1bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C - protection IP68 - PUR cable 12m; PVC wire insulation

Bajo consulta
496,62 €
sin IVA · 600,91 € con IVA

7ML5307-1AA06-0AA0, Radar level sensor, LR100

N.º cat.: 7ML5307-1AA06-0AA0

SITRANS LR100 radar level sensor, non-contact measurement up to a distance of 10m, designed for liquids and slurries, integrated cable length 10m, process connection with thread 1-1/2" NPT, cable…

Bajo consulta
552,71 €
sin IVA · 668,78 € con IVA

Los precios incluyen la tasa de reciclaje.

Level sensors

Choose a level sensor according to the information the process is to obtain. Continuous filling height, calculated volume and confirmation that a limit has been reached are three different results. A tank may need continuous measurement for the operators and separate limit monitoring for fill control. When specifying, therefore, first determine the measured quantity, the reference point and the required response of the equipment. Only then compare the probe design and electrical interface.

Principle according to tank and medium

The public range includes, for example, IFM LR3000 and PS3208, Siemens SITRANS LR100 and the Liquiphant FTL51. vibrating switch. These are not interchangeable designs. The manufacturer designates LR3000 as a guided wave radar, consisting of an evaluation unit and a probe. For media with low permittivity, it requires the appropriate coaxial version. PS3208 is a hydrostatic submersible probe. With it, the properties of the liquid and the tank conditions must be taken into account when interpreting the pressure.

In the enquiry, write the composition and temperature of the medium, foam formation, deposits, agitation, pressure above the level and obstacles inside the vessel. Attach a sketch with the position of the filling stream and the required sensing point. Such documentation helps reveal an unsuitable measuring point before the finished pipework or lid has to be changed. The housing material alone does not describe all the parts that will be in contact with the contents.

Height is not automatically volume

To convert the level to litres, you need the tank geometry or a verified conversion table. Also determine whether the display zero corresponds to the bottom, the probe position or the lowest usable level. It is precisely this definition that belongs in the handover documentation; without it, the reading "fifty percent" may have a different meaning for the operators and the programmer.

Author's example: usable stock

Consider a tank with a constant plan area of 0.80 m². The measured level is 0.65 m above the bottom, but pumping is to stop at 0.15 m. The geometric volume of the liquid is 0.80 × 0.65 = 0.52 m³, i.e. 520 litres. The usable stock above the switch-off level is only 0.80 × (0.65 − 0.15) = 0.40 m³, i.e. 400 litres.

The difference of 120 litres is not a sensor error but the difference between two definitions of stock. The dimensions and limits are chosen for the example, not parameters of the product offered. The calculation does not apply unchanged to a horizontal cylinder, a conical bottom or a tank with significant internal fittings.

Mounting and verification of the result

Before installation, verify the requirements of the selected principle for clearances, probe length, seals and fixing. Prepare access for removal and cleaning. During commissioning, compare the reading with the actual level at several points and test both filling and emptying. Separately record the behaviour with an empty tank, after power is restored and on loss of signal. In the control settings, an invalid value must not look like a normal zero stock.

For simpler mechanical monitoring, compare Float switches. Other principles and related products are grouped in Level sensors and probes.

FAQ

Will a limit switch show the exact number of litres?

A binary state alone does not provide such information. For continuous volume, you need a continuous quantity and correct conversion according to the tank.

Is one test with a full tank enough?

It will not verify behaviour across the whole working range. Include the lowest usable level, normal operation and transitions between states that the control system actually uses.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.