Level Sensors and Probes

Level sensors and probes for liquids and bulk solids – float switches, hydrostatic probes, ultrasonic and radar sensors. Choose by medium, tank type and whether you need continuous measurement or point level monitoring.

Subcategorías

Filtros
Encontrado 19 productos
−10 % EN STOCK

SKF1A-1, float switch, Emas

N.º cat.: SKF1A-1

SKF1A-1, float switch with cable length 1m, 1 changeover contact, Emas

En stock 3 ks
11,84 € 13,14 €
sin IVA · 14,32 € con IVA
−50 % EN STOCK

SKF-10, float switch, Emas

N.º cat.: SKF-10

SKF-10, float switch with cable length 10m, 1 changeover contact, Emas

En stock 5 uds. o más
17,03 € 34,02 €
sin IVA · 20,61 € con IVA
EN STOCK

SKF-0.5, float switch, Emas

N.º cat.: SKF-0.5

SKF-0.5, float switch with cable length 0.5m, 1 changeover contact, Emas

En stock 5 uds. o más
25,40 €
sin IVA · 30,74 € con IVA
−10 % EN STOCK

SKF1A-10, float switch, Emas

N.º cat.: SKF1A-10

SKF1A-10, float switch with cable length 10m, 1 changeover contact, Emas

En stock 2 ks
30,67 € 34,06 €
sin IVA · 37,11 € con IVA
−10 % EN STOCK

Ultrasonic sensor, 3RG6012-3AH00, AN, Siemens

N.º cat.: 3RG6012-3AH00

Ultrasonic sensor, 3RG6012-3AH00, SIEMENS

En stock 1 ks
378,79 € 420,88 €
sin IVA · 458,34 € con IVA
−10 % EN STOCK

Liquiphant FTL51-1KVK0/0, vibrating level limit switch Endress Hauser

N.º cat.: FTL51-1KVK0/0

Liquiphant FTL51-1KVK0/0, vibrating level limit switch Endress Hauser

En stock 1 ks
457,03 € 507,80 €
sin IVA · 553,01 € con IVA
−10 % EN STOCK

Time-of-Flight ultrasonic measurement Prosonic FMU41-ARB2A2, Endress Hauser

N.º cat.: FMU41-ARB2A2

Time-of-Flight ultrasonic measurement Prosonic FMU41-ARB2A2, Endress Hauser

En stock 2 ks
574,94 € 638,81 €
sin IVA · 695,68 € con IVA
−10 % EN STOCK

Time-of-Flight ultrasonic measurement Prosonic FMU41-1RB1A4, Endress Hauser

N.º cat.: FMU41-1RB1A4

Time-of-Flight ultrasonic measurement Prosonic FMU41-1RB1A4, Endress Hauser

En stock 1 ks
633,90 € 704,32 €
sin IVA · 767,02 € con IVA
−10 % EN STOCK

Time-of-Flight ultrasonic measurement Prosonic FMU41-JNB2C3, Endress Hauser

N.º cat.: FMU41-JNB2C3

Time-of-Flight ultrasonic measurement Prosonic FMU41-JNB2C3, Endress Hauser

En stock 4 ks
987,64 € 1 097,36 €
sin IVA · 1 195,04 € con IVA

SKF-5, float switch, Emas

N.º cat.: SKF-5

SKF-5, float switch with cable length 5m, 1 changeover contact, Emas

Bajo consulta
27,55 €
sin IVA · 33,33 € con IVA
NUESTRO CONSEJO

7ML5610-0BD20, capacitive level probe, Siemens

N.º cat.: 7ML5610-0BD20

measuring range 0 to 0.25bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C, protection IP68, PUR cable 3m; PVC wire insulation

Bajo consulta
227,65 €
sin IVA · 275,46 € con IVA
NUESTRO CONSEJO

Level sensor LR7000 IFM, LR0000B-BR34AQPKG/US

N.º cat.: LR7000

electrical design DC PNP, supply voltage 18 – 30 VDC, 2 switching outputs: 2x NO/NC programmable, medium temperature 0 +80°C, protection IP67, max. tank pressure -1 to 4bar, process connection G3/4…

Bajo consulta
342,68 €
sin IVA · 414,64 € con IVA
NUESTRO CONSEJO

Level sensor LR8000 IFM, LR0000B-BR34ASPKG/US

N.º cat.: LR8000

electrical design DC PNP, supply voltage 18 – 30 VDC, 4 switching outputs: 4x NO/NC programmable, medium temperature 0 +80°C, protection IP67, max. tank pressure -1 to 4bar, process connection G3/4…

Bajo consulta
397,50 €
sin IVA · 480,98 € con IVA
NUESTRO CONSEJO

Level sensor LR3000 IFM, LR0000B-BR34AMPKG/US

N.º cat.: LR3000

electrical design DC PNP, supply voltage 18 – 30 VDC, 2 independent output signals: OUT1 NO / NC, OUT2 analogue 4-20mA / 0-10V, medium temperature 0 +80°C, protection IP67 max. tank pressure -1 to…

Bajo consulta
405,57 €
sin IVA · 490,74 € con IVA
NUESTRO CONSEJO

Level probe PS3208 IFM, SUBMERSIBLE 0.25BAR 3M CABLE

N.º cat.: PS3208

measuring range 0 to 0.25bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C, protection IP68, PUR cable 3m; PVC wire insulation

Bajo consulta
437,30 €
sin IVA · 529,13 € con IVA
NUESTRO CONSEJO

Level probe PS3407 IFM, SUBMERSIBLE 0.6BAR 10M CABLE

N.º cat.: PS3407

measuring range 0 to 0.6bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C, protection IP68, PUR cable 10m; PVC wire insulation

Bajo consulta
481,60 €
sin IVA · 582,73 € con IVA
NUESTRO CONSEJO

Level probe PS3417 IFM, SUBMERSIBLE 1BAR 12M CABLE

N.º cat.: PS3417

measuring range 0 to 1bar, supply voltage 10 – 30 VDC, output signal: analogue 4-20mA, medium temperature -10 +50°C - protection IP68 - PUR cable 12m; PVC wire insulation

Bajo consulta
496,62 €
sin IVA · 600,91 € con IVA

7ML5307-1AA06-0AA0, Radar level sensor, LR100

N.º cat.: 7ML5307-1AA06-0AA0

SITRANS LR100 radar level sensor, non-contact measurement up to a distance of 10m, designed for liquids and slurries, integrated cable length 10m, process connection with thread 1-1/2" NPT, cable…

Bajo consulta
552,71 €
sin IVA · 668,78 € con IVA

Los precios incluyen la tasa de reciclaje.

Level sensors and probes

Level can be monitored as a limit state, a continuous height or a value converted to volume. These tasks require different solutions. A float can confirm that a sump is full, but on its own it does not create a continuous record of the stock. A continuous sensor, on the other hand, needs the correct reference plane and tank geometry if its reading is to be used for balancing.

The range includes EMAS SKF float switches, IFM PS hydrostatic probes, IFM LR and Siemens LR100, radar devices, Siemens Probe LU240 and Endress+Hauser FMU41 ultrasonic devices, and the Liquiphant FTL51. vibrating limit switch. These are different measuring principles, not interchangeable probes with universal accessories.

For mechanical limit detection, continue to the subcategory Float switches; other measuring versions can be found in the branch Level sensors. In both cases, choose according to the medium, mounting space and the required signal.

What the individual principles measure

IFM PS3208 submersible probe is offered with a range of 0–0.25 bar and a 3 m cable. Hydrostatic measurement evaluates the liquid pressure above the diaphragm. When converting to height, the density of the medium and the pressure above the level are decisive; the cable length is not a measuring range value.

IFM LR3000 is a guided wave radar. An electromagnetic pulse travels along the probe and returns from the medium interface. The choice of rod or coaxial assembly depends on the properties of the liquid and installation conditions; accessories cannot be chosen only by tank length.

Non-contact radar and ultrasound evaluate the reflection from the surface, but do not use the same waves. When designing, watch for foam, steam, condensation, agitators and obstacles in the measuring space. False reflections from the structure cannot be corrected merely by rewriting the volume scale. A float, in turn, needs free mechanical movement; the cable, wall or deposits must not prevent it from tilting.

Tank, medium and connection

In an open tank, the hydrostatic overpressure can be referenced to the ambient atmosphere. In a closed pressurised vessel, the gas pressure above the level is added. Without taking it into account correctly, the device cannot distinguish a change in height from a change in this pressure. For the related reference measurement, open the category Pressure sensors. Design the compensation method for the specific system, not by automatically subtracting two arbitrary sensors.

For the submersible version, check the diaphragm, seals and cable sheath; all of them may be wetted. If the probe uses a vent capillary, the termination must maintain the pressure reference and at the same time prevent ingress of moisture according to the manual. The degree of protection of the probe itself is not permission to submerge any cable joint. Separately assess cleaning chemicals, temperature and deposits on the sensitive surface.

During commissioning, verify zero, the upper working point and a reserve for surface waves. For pump switching, set the difference between the switch-on and switch-off levels so that normal surface movements do not cause frequent cycling. These limits must also respect the sump volume and pump operation.

Model calculation: influence of density

Assume an open tank, a homogeneous liquid and a measured hydrostatic overpressure of 0.20 bar, i.e. 20 000 Pa. For a model density of 1 000 kg/m³, h = p/(ρg) = 20 000/(1 000 × 9.81) ≈ 2.04 m. At a density of 850 kg/m³, the same pressure corresponds to approximately 2.40 m. The difference of about 0.36 m arises from a change of medium, not a change in the pressure signal. This is a physical model, not a declaration of the range or suitability of a specific probe for oil.

FAQ

Why does the level height not correspond to the litres in the tank?

Neither a horizontal cylindrical tank nor a tank with a conical bottom has a constant horizontal cross-section. You need a geometric or verified conversion table. Do not forget the sensor position, the unusable residue and the working range below the maximum permissible level.

Can a float switch a pump directly?

The current rating of the contact alone is not enough. Compare the permissible type of load with the motor start-up and the design of the switching circuit. The necessary contactors, fuses and protections are determined as a whole; they cannot be derived just from the number of wires of the float.

Is one sensor at the same time independent overfill protection?

Two set limits on one device do not create two independent measurements. A protective function must be addressed by a separate design. For links to control, alarms and other quantities, use the overview Process Sensors.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.