Flow sensor SI5004 IFM, SID10ADB100G/US-100
electrical design DC PNP, supply voltage 19 – 30 VDC, output function analogue 4 - 20mA, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, protection IP67, pressure rating…
Tipo de cambio 24,43 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
ifm SI series flow sensors for monitoring the flow of liquids and gases and SM flow meters for measuring flow and consumption. Choose by medium, range and output.
electrical design DC PNP, supply voltage 19 – 30 VDC, output function analogue 4 - 20mA, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, protection IP67, pressure rating…
electrical design DC PNP, supply voltage 19 – 30 VDC, output function NO/NC, programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, measuring range for gases 200…
electrical design DC PNP, supply voltage 19 – 30 VDC, 2 output functions: 1x NO/NC programmable 1x temperature monitoring, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s…
electrical design DC PNP, supply voltage 19 – 30 VDC, output function 2x NO/NC programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s measuring range for gases 200…
electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...25 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…
electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...50 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…
electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...100 l/min, medium temperature -10°C .. +70°C, protection IP67 - pressure rating 16bar - process…
SM6000, flow sensor; voltage: 19-30VDC; output: PNP/NPN; SMR12GGXFRKG/US-100, IFM
electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…
electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…
Los precios incluyen la tasa de reciclaje.
Should the equipment only confirm the flow of coolant, or do you need to record its flow rate and the quantity drawn? The difference affects the choice of sensor and the method of evaluation. A limit signal can serve well as an operating condition, but on its own it does not say how many litres have passed through the pipe. Therefore formulate the specification as a specific requirement for information, for example a drop in flow, instantaneous flow or dose total.
The range here includes, for example, SI5000, SI5004, SI5007, SM6000 and SM6050. IFM, for the SI calorimetric principle explains the sensing of heat removal by the flowing medium. It is a response at the location of the measuring tip. Local velocity cannot simply be declared the mean velocity of the entire pipe without knowing the velocity profile.
Product sheet SM6000 describes magnetic-inductive measurement of conductive liquids, quantity totalising and temperature monitoring. These are different operating information whose transfer to the control system depends on the configuration. Do not transfer the properties of SM6000 to other codes of the SM series without checking.
Describe the medium including its changes during operation, the normal and lowest flow, pressure and temperature. Decide whether the operators need local indication and whether the control system expects a contact, an analogue value or pulses. Then compare precisely these requirements with each candidate's datasheet. An identical connector does not yet mean an identical signal on the individual pins.
To check cooling, determine in advance a test that represents a real fault: for example, closing a branch or stopping the pump in a controlled test. Merely changing the sensor setting does not verify that its location will capture the problem in the required part of the circuit. With several parallel branches, it must be clear which branch the measurement actually represents.
At a model constant flow of 12 l/min, a volume of 12 × 45 / 60 = 9 litres passes in 45 seconds. For a separate example, assume pulse evaluation set to 0.10 litre per pulse. Nine litres correspond to 90 pulses. When the sensor setting is changed to 0.20 litre per pulse, the same nine-litre dose produces only 45 pulses. An unchanged program with a conversion of 0.10 litre per pulse then evaluates only 4.5 litres.
The time, flow and pulse value are chosen by the author, not the default settings of the products listed. With variable flow, the volume is obtained by summing the contributions over time. Moreover, the accuracy of the entire dose cannot be derived solely from the number of decimal places on the display.
Verify the required orientation, immersion of the tip or filling of the measuring tube and the lengths of the calming sections according to the manual of the selected model. Do not invent one common distance from a bend for all series. Ensure the possibility of checking deposits and service disconnection. After start-up, record the steady state, zero flow and the response during start-up; only adjust the limits and control timing according to the results.
A wider range is contained in Flow sensors. For separate temperature monitoring of the cooling circuit, continue to Temperature sensors.
It only confirms the evaluated state. Adequate cooling also depends on the liquid temperature and the requirements of the cooled equipment.
First compare outputs, scale, units and fault states. Verify compatibility throughout the chain from the sensor to the display.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.