TPU04, TECHNOLINE, straight fitting for Ø4mm tube
TPU04, TECHNOLINE, straight fitting for Ø4mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
Tipo de cambio 24,43 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
Push-in fittings for quick, tight connection of pneumatic tubes without tools – straight, elbow, branch and barb. Choose by tube outside diameter and shape.
TPU04, TECHNOLINE, straight fitting for Ø4mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
TPU06, TECHNOLINE, straight fitting for Ø6mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
TPV04, TECHNOLINE, elbow fitting 90° for Ø4mm tube. Change of line direction by 90° without a sharp tube bend right at the joint.
TPU08, TECHNOLINE, straight fitting for Ø8mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
TPV06, TECHNOLINE, elbow fitting 90° for Ø6mm tube. Change of line direction by 90° without a sharp tube bend right at the joint.
TPY04, TECHNOLINE, Y-connector for Ø4mm tube. Angled Y-branching for routing three branches with suitable tube geometry.
TPE04, TECHNOLINE, T-connector for Ø4mm tube. Branching into three pneumatic branches; the flow is divided according to consumption and line resistance.
TPY06, TECHNOLINE, Y-connector for Ø6mm tube. Angled Y-branching for routing three branches with suitable tube geometry.
TPE06, TECHNOLINE, T-connector for Ø6mm tube. Branching into three pneumatic branches; the flow is divided according to consumption and line resistance.
TPV10, TECHNOLINE, elbow fitting 90° for Ø10mm tube. Change of line direction by 90° without a sharp tube bend right at the joint.
TPY08, TECHNOLINE, Y-connector for Ø8mm tube. Angled Y-branching for routing three branches with suitable tube geometry.
TPU10, TECHNOLINE, straight fitting for Ø10mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
TPE08, TECHNOLINE, T-connector for Ø8mm tube. Branching into three pneumatic branches; the flow is divided according to consumption and line resistance.
TPU12, TECHNOLINE, straight fitting for Ø12mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
TPV12, TECHNOLINE, elbow fitting 90° for Ø12mm tube. Change of line direction by 90° without a sharp tube bend right at the joint.
TPZA04, TECHNOLINE, cross fitting for Ø4mm tube. Cross connection of four pneumatic branches at a single point.
TPGJ08-04, TECHNOLINE, plug-in reducer Ø8mm→Ø4mm. A plug-in adapter into a push-in counterpart with a separate tube connection.
TPE10, TECHNOLINE, T-connector for Ø10mm tube. Branching into three pneumatic branches; the flow is divided according to consumption and line resistance.
TPY10, TECHNOLINE, Y-connector for Ø10mm tube. Angled Y-branching for routing three branches with suitable tube geometry.
TPZA06, TECHNOLINE, cross fitting for Ø6mm tube. Cross connection of four pneumatic branches at a single point.
TPE12, TECHNOLINE, T-connector for Ø12mm tube. Branching into three pneumatic branches; the flow is divided according to consumption and line resistance.
TPZA08, TECHNOLINE, cross fitting for Ø8mm tube. Cross connection of four pneumatic branches at a single point.
TBPU04, TECHNOLINE, straight all-metal fitting for Ø4mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread. Metal body.
TPGJ10-06, TECHNOLINE, plug-in reducer Ø10mm→Ø6mm. A plug-in adapter into a push-in counterpart with a separate tube connection.
TPK04, TECHNOLINE, multi-way manifold for Ø4mm tube. A multi-way compressed air distributor for clear connection of consumer branches.
Los precios incluyen la tasa de reciclaje.
Select push-in fittings according to what they actually connect: two tubes, a tube with a threaded port, or a tube with the plug-in stem of another part. The range includes Pneuflex and SMC versions in various shapes and sizes. For ordering, therefore, first draw both opposite interfaces. The category name alone does not determine the design of each item.
Section of fitting KQ2 from SMC separates the gripping of the tube by a toothed element from its sealing. The release button engages the gripping. The sealing function and mechanical securing therefore have their own design elements.
The selection record should include the tube outer diameter, the full designation of the counterpart and the required line direction. Record the inner diameter separately for assessing the passage. For the thread, require its system and size; a value in inches without the system is not enough to decide on a replacement. Record separately whether you are selecting a thread for connecting the medium or a thread for fixing into the panel. The similar appearance of these points can hide a different purpose when ordering.
To continue in one axis, open Straight fittings, for changing direction Elbow fittings and for splitting the line Branch fittings. Our own practical rule is to select the functional diagram first and only then the smallest body. For a confined assembly, you also need to draw the access of fingers, tools and the path for pulling out the tube during replacement.
For a replacement part, prepare a simple diagram of the original and intended assembly. Both must show all ends that change during the intervention. If the replacement adds an adapter, also add the new detachable point and its accessibility. This gives you a basis for choosing between a direct replacement and a route change, without deciding solely by the size of the available component.
Before intervention, ensure the safe state of the equipment and verify that no pressure remains in the section being changed. For your own mounting check, compare the actual parts with the drawing, mark the individual branches and check access to all detachable points. Also record the fixing of the line around the fitting. The purpose of the check is to reveal whether future replacement of one tube will require dismantling other components.
Pneuflex for the straight PU family describes inserting the tube and releasing it by pressing the collet. Always relate the exact mounting procedure to the selected version.
Let us consider an explicitly model closed passage with a diameter of 5 mm and an overpressure of 0.7 MPa. A force F = p × A acts on the flat closure. The area A = π × 5² / 4 is approximately 19.6 mm²; since 0.7 MPa corresponds to 0.7 N/mm², the force is about 13.7 N. This is our own illustration of the effect of pressure, not the load capacity of the fitting, the tube pull-out force or the recommended working pressure of the product. The model explains why the state of a connection cannot be assessed by hand alone.
In the service record, separate a problem at the tube inlet, at the threaded counterpart and in the body of the assembly. Record whether the symptom appeared after replacement, during line movement or only during simultaneous consumption. Your own comparison procedure always changes a single circumstance: line layout, verified counterpart or specific connecting part. This way, a selection error can be distinguished from a mounting problem without randomly changing the whole branch.
Check which interface the value belongs to. Record the tube diameter, the plug-in stem diameter and the mounting hole size as different quantities.
Yes, take the specific service operation into account in the design. Assess the free space for inserting, releasing and pulling out the line, not just for the body dimension.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.