RZT7-03ZRS-KP0, SICK, magnetic sensor, 1070847
RZT7-03ZRS-KP0 SICK – magnetic sensor, M8. Industrial product for automation, detection or measurement.
Tipo de cambio 24,43 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
SICK magnetic sensors for piston position sensing (RZT, MZT, MZC), continuous MPS position measurement and RE safety door switches. Choose by purpose, slot and connection.
RZT7-03ZRS-KP0 SICK – magnetic sensor, M8. Industrial product for automation, detection or measurement.
MZT7-03VPS-KW0 SICK – magnetic sensor, PNP, NO, cable 2m. Industrial product for automation, detection or measurement.
MZC1-2V2PS-KP0 SICK – magnetic sensor, M8, PNP, Normally open contact, C. Industrial product for automation, detection or measurement.
RE13-SAC SICK – magnetic sensor, M8, Reed contacts. Industrial product for automation, detection or measurement.
RE27-SA68L SICK – magnetic sensor, M12, Reed contacts. Industrial product for automation, detection or measurement.
MZCG-1Z7PS-KR0 SICK – magnetic sensor, M8, PNP, Normally open contact, C. Industrial product for automation, detection or measurement.
MPS-032TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-064TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-064TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.
MPS-096TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-096TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.
MPS-128TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-128TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.
Los precios incluyen la tasa de reciclaje.
The range combines three different tasks: switching the piston position, continuous measurement of its position and safety monitoring of protective doors. In addition to versions MPS-032, MPS-064, MPS-096 and MPS-128 it includes RZT7, MZT7, MZC1, MZCG as well as RE13-SAC and RE27-SA68L. Before comparing parameters, therefore, determine which task the ordered part is to perform.
For a service replacement, separate mechanical from electrical compatibility. A similar designation or the same number of wires is not enough. Store the cylinder type, slot profile, expected input function and the exact code of the original sensor in the work sheet.
The specific MPS-064TSTU0, 1045669 is designed for the T-slot and has a measuring range of 64 mm, while the housing measures 77 mm. The sheet specifies analogue 0–10 V or 4–20 mA; the corresponding connected output is activated.
Consider MPS where the control system needs a position value within a defined section. Before ordering, draw the required limits, the space for the housing and the connection route. Prepare a suitable control input and scaling for the specific variant; do not transfer the parameters of this example to all MPS lengths.
RE1/RE2 are magnetic safety switches for movable guards in combination with a suitable safety evaluation unit. Selection requires a risk assessment and professional commissioning according to the SICK manual RE1/RE2. It is not a substitute for a standard cylinder sensor.
RE13-SAC, 1059503 contains a sensor with actuator, two switching contacts and a four-pole M8. RE27-SA68L, 1059509 additionally has a signalling contact and a 0.2 m cable with an eight-pole M12. Both sheets leave fault detection to the downstream safety logic. The PL achieved by the whole assembly therefore cannot be determined from the switch designation.
The position alone does not prove the clamping force or correct gripping of the part. Evaluate these requirements separately according to the machine.
No. Compare the number and assignment of contacts with the specific sheet and the approved wiring. Buying a cable does not replace the assessment of the safety circuit.
Other brands can be compared among magnetic sensors. For connection, continue with Sensor Cables and Connectors; selection documents are covered by technical support.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.