Rectangular and compact ultrasonic sensors

Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.

Filtros
Encontrado 202 productos

Ultrasonic sensor, diffuse 20x42x15,teach, UT210170

N.º cat.: UT210170

Ultrasonic sensor, diffuse 20x42x15,teach, DC,pnp,no,200mA,Sn:10-200,M8 connector4p

Bajo consulta
426,92 €
sin IVA · 516,57 € con IVA

URDK 30N3703/S14, BAUMER, ultrasonic retro-reflective sensor, 0–1000mm, NPN, normally closed (NC), connector M12, IP67

N.º cat.: URDK 30N3703/S14

URDK 30N3703/S14 – ultrasonic retro-reflective sensor BAUMER. Range 0–1000mm. Output NPN, normally closed (NC). Connector M12. IP67.

Bajo consulta
429,17 €
sin IVA · 519,30 € con IVA

URDK 30P3703/S14, BAUMER, ultrasonic retro-reflective sensor, 0–1000mm, PNP, normally closed (NC), connector M12, IP67

N.º cat.: URDK 30P3703/S14

URDK 30P3703/S14 – ultrasonic retro-reflective sensor BAUMER. Range 0–1000mm. Output PNP, normally closed (NC). Connector M12. IP67.

Bajo consulta
429,17 €
sin IVA · 519,30 € con IVA

URDK 30P7104/S14, BAUMER, ultrasonic retro-reflective sensor, 0–2000mm, PNP, normally closed (NC), connector M12, IP67

N.º cat.: URDK 30P7104/S14

URDK 30P7104/S14 – ultrasonic retro-reflective sensor BAUMER. Range 0–2000mm. Output PNP, normally closed (NC). Connector M12. IP67.

Bajo consulta
429,17 €
sin IVA · 519,30 € con IVA

Ultrasonic sensor, analogue, 20x42x15,teach, UT210075

N.º cat.: UT210075

Ultrasonic sensor, analogue, 20x42x15,teach, DC,0-10V,Sn:20-200mm,M8 connector4pol

Bajo consulta
430,38 €
sin IVA · 520,76 € con IVA

Ultrasonic sensor, analogue, 20x42x15,teach, UT210070

N.º cat.: UT210070

Ultrasonic sensor, analogue, 20x42x15,teach, DC,4-20mA,Sn:20-200mm,M8 connector4pol

Bajo consulta
430,38 €
sin IVA · 520,76 € con IVA

Ultrasonic sensor, UC500-L2-E6-V15, 188196, PEPPERL+FUCHS

N.º cat.: UC500-L2-E6-V15

Ultrasonic sensor, UC500-L2-E6-V15, 188196, PEPPERL+FUCHS

Bajo consulta
431,39 €
sin IVA · 521,98 € con IVA

Ultrasonic sensor, UC2000-L2-E6-V15, 188202, PEPPERL+FUCHS

N.º cat.: UC2000-L2-E6-V15

Ultrasonic sensor, UC2000-L2-E6-V15, 188202, PEPPERL+FUCHS

Bajo consulta
431,39 €
sin IVA · 521,98 € con IVA

Ultrasonic sensor, UC4000-L2-E6-V15, 188208, PEPPERL+FUCHS

N.º cat.: UC4000-L2-E6-V15

Ultrasonic sensor, UC4000-L2-E6-V15, 188208, PEPPERL+FUCHS

Bajo consulta
431,39 €
sin IVA · 521,98 € con IVA

Ultrasonic sensor, UC2000-F43-2KIR2-V17, 120329, PEPPERL+FUCHS

N.º cat.: UC2000-F43-2KIR2-V17

Ultrasonic sensor, UC2000-F43-2KIR2-V17, 120329, PEPPERL+FUCHS

Bajo consulta
440,34 €
sin IVA · 532,81 € con IVA

Ultrasonic sensor, UC300-F43-2KIR2-V17, 120332, PEPPERL+FUCHS

N.º cat.: UC300-F43-2KIR2-V17

Ultrasonic sensor, UC300-F43-2KIR2-V17, 120332, PEPPERL+FUCHS

Bajo consulta
440,34 €
sin IVA · 532,81 € con IVA

Ultrasonic sensor, retro-reflective 20x42x15,teach, UR210170

N.º cat.: UR210170

Ultrasonic sensor, retro-reflective 20x42x15,teach, DC,pnp,no,200mA,Sn:200,M8 connector4pol

Bajo consulta
444,14 €
sin IVA · 537,40 € con IVA

URDK 20P6914/S35A, BAUMER, ultrasonic retro-reflective sensor, 0–200mm, PNP, normally open (NO), connector M8, IP67

N.º cat.: URDK 20P6914/S35A

URDK 20P6914/S35A Baumer: ultrasonic retro-reflective sensor, 0–200 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE

Bajo consulta
458,04 €
sin IVA · 554,23 € con IVA

URDK 20P6912/S35A, BAUMER, ultrasonic retro-reflective sensor, 0–400mm, PNP, normally open (NO), connector M8, IP67

N.º cat.: URDK 20P6912/S35A

URDK 20P6912/S35A Baumer: ultrasonic retro-reflective sensor, 0–400 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE

Bajo consulta
458,04 €
sin IVA · 554,23 € con IVA

Los precios incluyen la tasa de reciclaje.

Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.

Illustrative rectangular BALLUFF ultrasonic sensor with front sensing face
Illustrative example of a design or application; verify the availability of the specific version on the product page.

Mounting in confined spaces

Compare the mounting holes, the position of the active surface and the cable or connector outlet. A low installation height does not mean that any obstacle can be placed in front of the face. Surrounding brackets and walls can reflect sound and affect detection. Also leave access to the setting buttons and indicators.

Range and electrical function

The design size does not indicate the measuring range. Verify the minimum and maximum working distance, blind zone and detection diagram for a suitable target. The switching version transmits a state; the analogue variant provides a continuous signal. Assess PNP/NPN, current or voltage analogue and communication separately from the NO/NC logic.

  • Record the size of the target, extreme distances and required response speed.
  • Compare the supply, output load capacity and control system input.
  • Verify the contact assignment and the mechanical design of the connection.
  • Check the degree of protection, temperature range and cleaning conditions of the variant.

Example of a rectangular design

BALLUFF BUS006H,, designated BUS Q62K1-PWX-60/600-S92K,, is listed by the manufacturer as a rectangular version with two PNP NO/NC switching outputs and a five-pin M12 connector. This is an example of a design; the same parameters cannot be transferred to the entire Q62 series or to other rectangular sensors.

What to verify before commissioning

Carry out a test with the actual material and in all working positions. When several ultrasonic sensors operate together, verify mutual interference. Take the settings and any synchronisation from the manual of the exact order code.

All ultrasonic sensors and selection guide · Sensor Cables and Connectors

Technical documents: Technical data BALLUFF BUS006H · Mounting ultrasonic sensors – microsonic.

Selection questions

When to choose a rectangular sensor instead of a cylindrical one?

A rectangular or flat housing is suitable where its mounting holes, height or direction of the active surface fit better. Decide according to the drawing and the space for the cable and sound beam.

Does a compact housing always have a shorter measuring range?

The housing shape alone does not determine the range. For each variant, compare the working distance, blind zone, response and target size given in the detection diagram.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.