IKM5KE, EMAS, 50 mm signal module, red, 24V DC, 50 mm, IP65
IKM5KE EMAS - signal module 50 mm, red, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
Tipo de cambio 24,47 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
Individual modules and accessories for EMAS 50 mm IP65 beacons for assembling or repairing the beacon.
IKM5KE EMAS - signal module 50 mm, red, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
IKM5YE EMAS - signal module 50 mm, green, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
IKM5RE EMAS - 50 mm signalling module, yellow, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
IKM5BE EMAS - 50 mm signal module, white, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
IKM5ME EMAS - 50 mm signal module, blue, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.
Los precios incluyen la tasa de reciclaje.
When servicing a lamp from the IP65 branch, you need to determine not only the color of the replacement part, but also its construction. In the catalog, for example, there are white IKM5BE and blue IKM5ME modules without LED bulbs. The optical module, light source, and base perform different tasks; distinguish them in the service order.
EMAS Catalogue denotes IKM5G as a body with a 50 mm diameter cap.
When replacing the base, request confirmation that the specific construction being supplied matches the repaired column. The same code in the list does not yet describe all installation conditions. Compare the mounting points, the closure of the upper part, and the cable routing. Do not return a damaged or unidentifiable part simply because it can be fitted with an additional layer.
In the overview Economic beacons - diameter 50mm EMAS (IP65) Check the continuity with the original construction. Do not omit the letter E when ordering if it is part of the identification of the smaller module. When replacing a visually similar part from another branch, specify the details, do not generalize from the same diameter.
Do not add tight-fitting material or new openings without a foundation for the given construction. Such an action changes the conditions of the original construction. Lighting all floors after repair confirms the electrical function, but does not prove the restored cover.
Consider a column with a burnt white segment marked IKM5BE. Maintenance compares the replacement part with the original and checks the neighboring contacts and closing parts. The source orders separately only if a replacement is also needed. After installation, verify the response to the relevant command and record the action. When the origin of other parts is unclear, compare the repair with the specified replacement. Compound beacons.
This cannot be confirmed without proof of the resulting configuration. The production catalogue for the IP65 version provides an exception for the horn.
Only if it complies with voltage, function and mechanical execution and has not been damaged. Consider the cause of the original defect so that it does not repeat after repair.
No. It continues to be used for operational information. The service of individual modules does not add safety function.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.