LCS-T1-2Nm, SMOWO, torque sensor, 2 Nm, PVC cable 2m with 4 PIN connector
LCS-T1-2Nm SMOWO – torque sensor, 2 Nm, PVC cable 2m with 4 PIN connector. Industrial product for automation, measurement and control.
Tipo de cambio 24,43 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
SMOWO torque sensors for measuring torque on a shaft. Choose by range, design and output.
LCS-T1-2Nm SMOWO – torque sensor, 2 Nm, PVC cable 2m with 4 PIN connector. Industrial product for automation, measurement and control.
LCS-T1-5Nm SMOWO – torque sensor, 5 Nm, PVC cable 2m with 4 PIN connector. Industrial product for automation, measurement and control.
LCS-T1-1Nm SMOWO – torque sensor, 1 Nm, PVC cable 2m with 4 PIN connector. Industrial product for automation, measurement and control.
LCS-T1-10Nm SMOWO – torque sensor, 10 Nm, PVC cable 2m with 4 PIN connector. Industrial product for automation, measurement and control.
LCS-T1-20Nm SMOWO – torque sensor, 20 Nm. Industrial product for automation, measurement and control.
Los precios incluyen la tasa de reciclaje.
Choose a torque sensor according to the working range, mounting method and movement of the measured part. This category is represented by the SMOWO LCS-T1. series. For checking a tightening fixture or reaction torque, it is essential to know whether it is a steady load, a short event or a continuously rotating shaft. These tasks are not interchangeable.
The manufacturer specifies LCS-T1 for static tests and non-continuous rotation. It states an output sensitivity of 1.0–1.5 mV/V and excitation of 5–12 V with 10 V recommended; verify the specific conversion for the selected variant. Suitability for continuous shaft rotation cannot be derived from this specification. The basis is SMOWO documentation LCS-T1. When designing the fixture, also check the cable routing throughout the permitted movement.
Torque depends on both force and lever arm: with perpendicular action, M = F × r. With an oblique direction, the perpendicular distance of the axis from the line of action of the force is decisive. The same force gauge with levers of different lengths therefore represents a different torque. For separate measurement of tensile or compressive force, use Strain gauge sensors; merely changing the units of their output does not create torque measurement.
Distinguish between a reaction arrangement and measurement on a rotating element. At the same time, assess radial and axial forces as well as bending, which the fixture or a misaligned coupling can add to the measuring point. These relationships are summarised by the NI torque measurement guide. Nominal torque does not automatically mean that any combination of side loads is permissible.
Before manufacturing adapters, check the dimensional drawing, connection interface and torque transmission path. The fixture should load the specified axis; it must not force the position of the sensor by elastic bending of the brackets. In the work procedure, define the positive direction and keep it for wiring, evaluation and reference testing.
For a small output in mV/V, you need a suitable measuring input. When choosing from strain gauge amplifiers compare the supported sensitivity, excitation voltage, zero offset and any negative signal. The transmitter supply is not automatically the sensor excitation. For a bidirectional test, it is not enough to set the device only for the positive part of the range; both directions must also be accepted by the subsequent analogue input or data processing.
A known force of 20 N acts perpendicularly on a horizontal arm 0.15 m long. The ideal torque is 3 N·m. Moving the same force to a distance of 0.30 m creates 6 N·m, not a greater force. For a measuring range of 5 N·m, the second arrangement would already exceed the nominal value. This own calculation assumes a rigid lever, a precisely defined axis and a perpendicular direction; it does not include friction, the weight of the fixture or start-up shock. It does not replace calibration of the finished equipment.
For calibration, determine the required range, direction and loading mode. The method must correspond to the use; a static reference alone does not verify the dynamic response. The choice of calibration and test methods is addressed by the NPL metrology guide for torque transducers. Zeroing without load does not replace checking the conversion at a known torque.
When evaluating a peak, check the entire time response. Averaging can reduce the measured maximum even though the steady value remains correct. Record the filter setting, the rate of genuinely new samples and the length of the event examined; communication frequency is not the same as measuring bandwidth.
Not without verification. Both the mechanical specification of the sensor and the electrical range of the entire assembly must be suitable. The sign in the program only describes the agreed orientation.
Zero helps separate the initial state but can hide a preload of the fixture. First check the mechanical unloading and only then store the zero reference.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.