AD16-22W / N31, APT, Power on indicator light, round, 230V AC
AD16-22W / N31 APT - signalling element, red, 230V AC. Technical specifications, use and selection of variants.
Tipo de cambio 24,47 Kč por 1 EUR. Los precios son orientativos; la facturación se realiza en coronas checas.
Other signalling devices – panel horns, power indicators and APT and EMAS signal crosses. Choose by signalling type, voltage and mounting.
AD16-22W / N31 APT - signalling element, red, 230V AC. Technical specifications, use and selection of variants.
AD16-22WF / D31 APT - component of industrial automation, red, 230V AC, 22 mm. Technical specifications, use and selection of variants.
MBZX220S EMAS - panel acoustic / light signalling, black, 230VAC, 22 mm. Technical specifications, use and selection of variants.
MBZS220S EMAS - panel acoustic / light signalling, red, 230VAC, 22 mm. Technical specifications, use and selection of variants.
MBZX024S EMAS - panel acoustic / light signalling, black, 24V AC / DC, 22 mm. Technical specifications, use and selection of variants.
MBZS024S EMAS - panel acoustic / light signalling, red, 24V AC / DC, 22 mm. Technical specifications, use and selection of variants.
AD16-22W/G23 APT - industrial automation component, red, 24 V AC / DC, 22 mm. Technical specifications, use and selection of variants.
Los precios incluyen la tasa de reciclaje.
This category brings together special panel signals: power and condition indicators, signal crosses and acoustic horns. Individual elements are not interchangeable. First, determine whether the operator should see, hear or need a combination of both ways.
Compare for example MBZX024S and MBZS024S. The EMAS manufacturer distinguishes the first as an acoustic element and the second as an LED implementation; both variants have a power supply of 24 V AC/DC. A range includes other voltage variants, so the entire code must be compared. See Official MB series overview by EMAS.
If light and sound perform different functions, for example keeping a light alert after muting the sound, first check whether the specific component allows their independent control. The description 'buzz with light' does not guarantee this feature. Another composition or separate system outputs may be needed.
The presence detection control is not a no-power state indicator. Turning off can mean a fault signal or its supply, not the safe disconnection of all parts of the device. Similarly, the checkmark symbol alone does not guarantee that the actual mechanical position or checkmark equipment is being monitored; it determines the connection and source of information.
Traffic lights or buzzers can be part of a traffic information system. However, they cannot be assigned a safety function, PL level, or SIL without a detailed design and assessment. Alerts on status and ensuring safe status are different tasks.
These are questions for control design, not for functions automatically included in each buzzer. Example: confirming an alarm receipt may only mute the sound while the cause is still ongoing. Maintenance must have the option to distinguish 'alarm confirmed' from 'fault removed'. Specific implementation depends on hardware and device software.
The volume must be compared with the measurement conditions stated in the documentation. The number in decibels does not guarantee hearability at any distance. When designing, consider machine noise, panel location, obstacles, and typical maintenance position. At the same time, unnecessary noise should not burden the surroundings; suitability is verified in the conditions of the specific workplace.
For spatial optical signalling, compare also signalling beaconsFor a simple indication of one condition are determined Panel indicator light 22 mm.
No. Memory, confirmation and reset are functions that must be explicitly documented at the device or created in a superior control.
No. A similar appearance or mounting dimension does not provide electrical interchangeability.
Details on selection summarises signalling guideIn case of confusion, use Technical support with specific ordering codes and functional input. Electrical assembly must be performed by a competent person; the text does not replace the project or safety assessment.
Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.
Elige qué cookies podemos usar. Puedes cambiar tu elección en cualquier momento.
Guardan el contenido del carrito, el inicio de sesión y el idioma elegido, y protegen los formularios frente a abusos. Sin ellas no se puede finalizar el pedido, por eso se utilizan incluso sin consentimiento.
Google Analytics nos muestra de forma agregada el tráfico y el comportamiento en el sitio. Así sabemos qué páginas no funcionan para los usuarios. Con estos datos no identificamos a nadie.