Phone +420 774 723 123 Cart · 0 · empty
AirBox 5/3 closed 4DI II 3D, AC570A, IFM

AirBox 5/3 closed 4DI II 3D, AC570A, IFM

Cat. no.: AC570A
Manufacturer: IFM
On request
Our price excl. VAT
375,72 €
incl. VAT 21 %
454,63 €

Description

 
Electrical design 4 inputs / 2 outputs; AirBox supply via AS-i
Output common exhaust with tube connection
Operating voltage [V]26.5...31.6 DC
Total current consumption from AS-i [mA]< 280
 
Inputs
Input circuit
DC PNP
Sensor supply AS-i
Voltage range [V]20...30 DC *)
Max. current load for all inputs total [mA]200
Short-circuit proof yes
Switching level High signal 1 [V]> 11
Input current High/Low [mA]> 6 / < 2
AS-Interface / extended addressing mode possible version 2.11 and 3.0 / yes
 
Outputs
Pneumatic system 1 x 5/3-way slide valve (free from overlapping); middle position blocked
Operating pressure range [bar]3...8
Air flow at 6/5 bar [l/min]400
Operating medium to ISO 8573-1 non-lubricated compressed air class 6-3-1; lubricated compressed air class 6-3-4 ¹)
Manual override pressing/releasing or pressing/turning/locking
Integrated watchdog yes
Tube fitting [mm] 8
 

AC570A
Ambient temperature [°C]-10...50
Protection IP 6X
AS-i profile S-7.A.E
I/O configuration [hex] 7
ID code [Hex] A.E
AS-i certificate in preparation
EMC
EN 50295 
IEC 61000-6-2 
MTTF [Years]258
Marking of the unit II 3D Ex tD A22 IP6X T80°C X Ta: -10...50°C
Housing materials PA; POM
Function display
Operation LEDgreen
Error LEDred
Function LEDyellow
 
Data bits
Data bitD0D1D2D3
Input1234
SocketI-1/2I-1/2 I-2I-3/4I-3/4 I-4
Pin42 442 4
Pneumatic output24--
 
Weight [kg]0.409
Remarks
The unit must only be installed together with the impact protection housing (E7000A) unless mechanical protection is implemented by means of other measures.
Do not connect any of the points L-, L+, I-1, I-2, I-3, I-4 to an external potential since they are electrically connected to the AS-i cable.
*) via flat cable
1) Notes on compressed air and EMC/ESD at www.ifm.com
Accessories (included) lower part
Accessories (optional)
Mounting plate (E74999)
Module lower part (E75000)
M12 protective cap (E73004)
impact protection housing (E7000A)
Silencer (E75232)
Push-in L-fitting (E75228)
Push-in T-fitting (E75227)
Pneumatic symbol
1 x 5/3-way slide valve (free from overlapping); middle position blocked
 
Wiring
Inputs
1: sensor supply L+
3: sensor supply L-
5:
We reserve the right to make technical alterations without prior notice.  —  GB  —  AC570A  —  05.12.2008

Technical parameters

Objednací kódAC570A
VýrobceIFM

Ask about this product

Ask us about technical parameters, compatibility with your equipment, availability or a price for larger quantities. It helps if you tell us what application you need the product for — if it does not fit, we will recommend a more suitable type.

Kód k opsání. Pokud ho nepřečtete, klikněte na Načíst nový kód.
The question relates to product AC570A

By sending you agree to the processing of the data provided for the purpose of handling your question. We do not pass the data on to third parties.

Related products