Phone +420 774 723 123 Cart · 0 · empty
US40-CC50DPH-E2, LANBAO, ultrasonic sensor, Sn 40–500 mm, connector M12/4 pins

US40-CC50DPH-E2, LANBAO, ultrasonic sensor, Sn 40–500 mm, connector M12/4 pins

Cat. no.: US40-CC50DPH-E2
Manufacturer: Lanbao
On request
Our price excl. VAT
139,43 €
incl. VAT 21 %
168,72 €
Recycling fee 5-32-1 (0,041 €/kg) 0,00 €
Weight 0.12 kg
HS Code (Taric) 85365019
Country of origin CN

Description

Delivery on request  ·  Genuine LANBAO  ·  Free technical support  ·  Invoice and delivery from the Czech Republic

US40-CC50DPH-E2 – Ultrasonic distance sensor

LANBAO US40-CC50DPH-E2 ultrasonic distance sensor for reliable detection in machines and production lines. It measures the time of flight of an ultrasonic pulse reflected from the object, so it works regardless of the colour, gloss and transparency of the material.

Key features

  • Sensing distance 40–500 mm.
  • Supply 20–30 V DC.
  • Connection: connector M12.
  • Degree of protection IP67 – protection against dust and temporary immersion.

Technical specifications US40-CC50DPH-E2

Order code US40-CC50DPH-E2
Manufacturer LANBAO
Housing material copper-nickel plating
Sensing distance (Sn) 40–500 mm
Supply voltage 20–30 V DC
Connection connector M12
Degree of protection IP67

Wiring of US40-CC50DPH-E2 by wire colours

Pin Cable wire colour Wiring
1 brown (BN) + supply (L+), 20–30 V DC
2 white (WH) Teach-in – wire for setting the sensing distance (A1, A2)
3 blue (BU) − supply (M / 0 V)
4 black (BK) output – switching or analogue depending on the model type

Setting the sensing distance (Teach-in): set point A2 by connecting the white wire to the brown (plus), point A1 by connecting the white wire to the blue (minus). Place the object at the required distance, connect the wires for two to three seconds until the blue indicator starts flashing, then disconnect the white wire. Teaching is active only for the first five minutes after switching on; after that the sensor must be switched on again.

Do not set points A1 and A2 closer than 20 mm from the blind zone, otherwise measurement accuracy and stability suffer. After switching on, the sensor warms up – it reaches full accuracy after about half an hour of operation.

The colour coding complies with IEC 60947-5-2. Always compare the actual pin and wire assignment with the diagram in the sensor datasheet (Downloads tab).

Pin assignment of US40-CC50DPH-E2, Teach-in on pin 2

Pin assignment according to the manufacturer's catalogue. Pin 2 (white) is the Teach-in wire, not an output.

Connection cable for US40-CC50DPH-E2

The sensor has a connector M12, 4 pins, male (external thread with pins), so it requires a cable with a femaleconnector. The cable is not included.

  • QE12-N4G5-N – M12, 4 pins, female, angled 90°, 5 m, PVC, with LED indication
  • QE12-N3G5-P – M12, 3 pins, female, angled 90°, 5 m, PVC, with LED indication PNP
  • QE12-N3G5-N – M12, 3 pins, female, angled 90°, 5 m, PVC, with LED indication NPN

The sensor has one output, so a three-pin cable is sufficient. A four-pin cable can also be used – the fourth wire remains unconnected.

PUR version: we do not yet stock a M12 female cable with a PUR jacket (for oils, coolant emulsions, abrasion, low temperatures and drag-chain installation). Contact us and we will source it. A cable with a PVC jacket is intended for normal dry machine environments.

The LED indication of the switched output in the connector is designed for the PNP NO version. With other output combinations the cable works electrically, but the indicator may not show switching – in that case choose a cable without indication.

Typical applications

  • level measurement and monitoring of liquids and bulk solids
  • detection of transparent objects to which optics do not respond
  • distance measurement and position monitoring in dusty environments
  • checking stack height or silo filling
  • detection of shiny and dark surfaces

How to choose and what to watch out for

  • Connector connection M12: a separate connection cable with a matching connector is required for operation – you will find it in the Cables with connector category.
  • Degree of protection IP67: protection against dust and temporary immersion. Not designed for permanent immersion or high-pressure washing – this requires IP69K.

Similar models in the same series

Frequently asked questions

What is the sensing distance of US40-CC50DPH-E2?

The sensing distance (Sn) is 40–500 mm.

How is US40-CC50DPH-E2 connected?

US40-CC50DPH-E2 is supplied with the connection: connector M12. A connection cable with a matching connector must be ordered separately.

How is the sensing distance set on US40-CC50DPH-E2?

Using the Teach-in function via the white wire. Connecting the white wire to the brown sets point A2,; connecting it to the blue sets point A1. Teaching is active only for the first five minutes after switching the sensor on.

Which cable do I need for US40-CC50DPH-E2?

Cable with a female M12 connector. We stock QE12-N4G5-N (4 pins, 5 m, PVC); for sensors with one output, three-pin QE12-N3G5-P or QE12-N3G5-N. can also be used. The cable is not included.

Does ultrasound detect transparent and shiny objects?

Yes. Ultrasound works with sound, not light, so transparency, colour or gloss do not matter. On the other hand, very soft and porous materials that absorb sound cause problems.

We supply US40-CC50DPH-E2 from the Czech Republic with an invoice and technical support. Not sure which one to choose? Send us your application parameters and we will recommend a suitable model.

Do you have a sensor from another manufacturer on your machine – SICK, IFM, Balluff, Omron or Pepperl+Fuchs? Send us its order code and we will cross-reference it to the matching LANBAO model.

Technical parameters

Objednací kódUS40-CC50DPH-E2
VýrobceLanbao
Housing sizeS40
Minimum sensing distance [mm]40
ConnectionConnector M12/4
Supply voltage [V DC]20–30
Switching functionHysteresis
Switching outputPNP
SynchronizationYes
DesignRectangular / compact
Analog outputNone
Communication interfaceNone
Maximum range [mm]500
Degree of protectionIP67
AdjustmentTeach-in
Blind zone [mm]0–40

Ask about this product

Ask us about technical parameters, compatibility with your equipment, availability or a price for larger quantities. It helps if you tell us what application you need the product for — if it does not fit, we will recommend a more suitable type.

Kód k opsání. Pokud ho nepřečtete, klikněte na Načíst nový kód.
The question relates to product US40-CC50DPH-E2

By sending you agree to the processing of the data provided for the purpose of handling your question. We do not pass the data on to third parties.

Related products

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.