Phone +420 774 723 123 Cart · 0 · empty
CR12SCF02DPO-E2, LANBAO, capacitive sensor, M12 plastic cylindrical, PNP, NO, connector M12/4 pins

CR12SCF02DPO-E2, LANBAO, capacitive sensor, M12 plastic cylindrical, PNP, NO, connector M12/4 pins

Cat. no.: CR12SCF02DPO-E2
Manufacturer: Lanbao
On request
Our price excl. VAT
22,56 €
incl. VAT 21 %
27,29 €
Recycling fee 5-32-1 (0,041 €/kg) 0,00 €
Weight 0.03 kg
HS Code (Taric) 85365019
Country of origin CN

Description

Delivery on request  ·  Genuine LANBAO  ·  Free technical support  ·  Invoice and delivery from the Czech Republic

CR12SCF02DPO-E2 – Capacitive proximity sensor

CR12SCF02DPO-E2 from LANBAO is a capacitive proximity sensor, version M12 plastic cylindrical designed for continuous industrial operation. It responds to a change in capacitance in the electric field in front of the face, so it detects both metals and non-metals — plastic, glass, wood, paper, liquids and bulk materials.

Key features

  • PNP output, NO contact – normally open – connects to a PLC digital input or a relay coil.
  • Supply 10–30 V DC.
  • Flush mounting.
  • Connection: connector M12.
  • Degree of protection IP67 – protection against dust and temporary immersion.
  • Operating temperature −25 to +70 °C.

How a capacitive sensor works

The sensor face consists of two electrodes between which an electric fieldis created. When any object enters the field, it changes its capacitance — and as soon as the change exceeds the set threshold, the sensor switches. Because it is not a magnetic field, it responds to both metals and non-metals: plastic, glass, wood, paper, liquids and bulk materials.

Capacitive sensor principle: electrodes and electric field

Principle of electrostatic capacitance: the field between the electrodes and its change when an object enters.

What the sensing distance depends on

The decisive factor is the relative permittivity of the material. Water and metals have a high value, so the sensor detects them at the greatest distance. Dry granulate, paper or foam materials have a low value and the range is significantly shorter. Therefore always allow a margin, and for level monitoring through a vessel wall choose the thinnest possible non-conductive wall.

Technical specifications CR12SCF02DPO-E2

Order code CR12SCF02DPO-E2
Manufacturer LANBAO
Size / housing M12 plastic cylindrical
Housing material PBT
Mounting / face design flush
Output type PNP
Contact function NO – normally open
Supply voltage 10–30 V DC
Connection connector M12
Degree of protection IP67
Operating temperature −25 to +70 °C
HS code (TARIC) 85365019
Country of origin CN

Wiring of CR12SCF02DPO-E2 by wire colours

Pin Cable wire colour Wiring
1 brown (BN) + supply (L+), 10–30 V DC
2 white (WH) not connected
3 blue (BU) − supply (M / 0 V)
4 black (BK) PNP output – NO – switches on detection; switches the positive pole – for a sinking-type PLC input

The sensor uses pins 1, 3 and 4 of the M12, connector, so a three-pin cable M12 is sufficient; a four-pin cable can also be used.

The colour coding complies with IEC 60947-5-2. Always compare the actual pin and wire assignment with the diagram in the sensor datasheet (Downloads tab).

Connector pin assignment of CR12SCF02DPO-E2

Connector pin assignment according to the manufacturer's catalogue.

Mounting and free space

The sensor has a flush sensing face, so it can be screwed into a metal structure right up to the face without affecting its function. The trade-off is a shorter sensing distance compared to the non-flush version.

Flush mounting of an inductive sensor

Flush mounting: the face may be level with the metal.

Mutual interference of sensors

Two sensors mounted close to each other may interfere with each other. If you need to sense at two adjacent points, keep the lateral spacing given in the sensor's dimension drawing, or offset the sensors so that their faces do not point into the same space.

Connection cable for CR12SCF02DPO-E2

The sensor has a connector M12, 4 pins, male (external thread with pins), so it requires a cable with a femaleconnector. The cable is not included.

  • QE12-N4G5-N – M12, 4 pins, female, angled 90°, 5 m, PVC, with LED indication
  • QE12-N3G5-P – M12, 3 pins, female, angled 90°, 5 m, PVC, with LED indication PNP
  • QE12-N3G5-N – M12, 3 pins, female, angled 90°, 5 m, PVC, with LED indication NPN

The sensor has one output, so a three-pin cable is sufficient. A four-pin cable can also be used – the fourth wire remains unconnected.

PUR version: we do not yet stock a M12 female cable with a PUR jacket (for oils, coolant emulsions, abrasion, low temperatures and drag-chain installation). Contact us and we will source it. A cable with a PVC jacket is intended for normal dry machine environments.

The LED indication of the switched output in the connector is designed for the PNP NO version. With other output combinations the cable works electrically, but the indicator may not show switching – in that case choose a cable without indication.

The same sensor with a different connection

Typical applications

  • monitoring the level of liquid or granulate through a vessel wall
  • detection of plastic and glass packaging on the line
  • checking the presence of cardboard, paper or a wooden board
  • sensing bulk materials in hoppers and silos
  • detection of parts to which an inductive sensor does not respond

How to choose and what to watch out for

  • Flush mounting: the sensor can be screwed into a metal structure right up to the face without affecting its function. Compared to the non-flush variant, however, it has a shorter sensing distance.
  • PNP output (switches plus) matches the standard PLC digital inputs used in Europe. For NPN-type inputs, choose the corresponding variant with the same sensing distance.
  • NO contact (normally open): the output is activated when an object is detected. If you need the opposite logic, an NC variant is available.
  • Connector connection M12: a separate connection cable with a matching connector is required for operation – you will find it in the Cables with connector category.
  • Degree of protection IP67: protection against dust and temporary immersion. Not designed for permanent immersion or high-pressure washing – this requires IP69K.
  • Operating temperature −25 to +70 °C applies to continuous operation. Short-term exceedance shortens service life and may permanently degrade the sensing distance.

PNP or NPN – and what happens if you mix them up

PNP switches the positive pole, so it sends plus to the PLC input. It is the European standard and matches standard digital inputs. NPN switches minus and is used mainly in Asian equipment. If mixed up, the sensor either does not switch at all or reports a permanently active state — it usually will not be damaged, but it will not work.

This model has a PNPoutput. If you need NPN, a variant with the same sensing distance is available — contact us and we will recommend the code.

NO or NC – and why it is not just a matter of convenience

NO (normally open) is an output that is active on detection. NC (normally closed) is active at rest and opens on detection. The difference is a safety one: with NC, a broken wire causes the same reaction as a detection, so the fault shows up immediately. With NO, a broken cable remains unnoticed until someone tries to switch.

This model has the contact NO – normally open.

Similar models in the same series

Frequently asked questions

Does CR12SCF02DPO-E2 have a PNP or NPN output?

CR12SCF02DPO-E2 has a PNP output with an NO contact – normally open. It therefore matches the standard PLC digital inputs used in Europe.

How is CR12SCF02DPO-E2 connected?

CR12SCF02DPO-E2 is supplied with the connection: connector M12. A connection cable with a matching connector must be ordered separately.

How many pins should the cable for CR12SCF02DPO-E2 have?

The sensor uses pins 1, 3 and 4, so a three-pin cable is sufficient; a four-pin cable can also be used. The signal is on the black wire, plus on the brown and minus on the blue.

Which cable do I need for CR12SCF02DPO-E2?

Cable with a female M12 connector. We stock QE12-N4G5-N (4 pins, 5 m, PVC); for sensors with one output, three-pin QE12-N3G5-P or QE12-N3G5-N. can also be used. The cable is not included.

Does a capacitive sensor detect through a vessel wall?

Yes, with a sufficient sensing distance and a thin non-conductive wall, the level can be monitored from outside. However, the sensing distance depends on the dielectric properties of the material — water can be detected at a greater distance than dry granulate.

We supply CR12SCF02DPO-E2 from the Czech Republic with an invoice and technical support. Not sure which one to choose? Send us your application parameters and we will recommend a suitable model.

Do you have a sensor from another manufacturer on your machine – SICK, IFM, Balluff, Omron or Pepperl+Fuchs? Send us its order code and we will cross-reference it to the matching LANBAO model.

Technical parameters

Objednací kódCR12SCF02DPO-E2
VýrobceLanbao
Mounting (flush/non-flush)Yes
SizeM12
Sensing2mm
ConnectionConnector M12/4 pins
Power supply10–30VDC
ContactNO
SwitchingPNP
Overall length65mm

Ask about this product

Ask us about technical parameters, compatibility with your equipment, availability or a price for larger quantities. It helps if you tell us what application you need the product for — if it does not fit, we will recommend a more suitable type.

Kód k opsání. Pokud ho nepřečtete, klikněte na Načíst nový kód.
The question relates to product CR12SCF02DPO-E2

By sending you agree to the processing of the data provided for the purpose of handling your question. We do not pass the data on to third parties.

Related products

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.