Phone +420 774 723 123 Cart · 0 · empty
OUR TIP
LR18XCF05ATC, LANBAO, inductive sensor 2-wire, M18, Sn 5 mm, 2-wire, NC, cable 2 m

LR18XCF05ATC, LANBAO, inductive sensor 2-wire, M18, Sn 5 mm, 2-wire, NC, cable 2 m

Cat. no.: LR18XCF05ATC
Manufacturer: Lanbao
On request
Our price excl. VAT
20,51 €
incl. VAT 21 %
24,82 €
Recycling fee 5-32-1 (0,041 €/kg) 0,00 €
Weight 0.1 kg
HS Code (Taric) 85365080
Country of origin CN

Description

Genuine LANBAO  ·  Free technical support  ·  Invoice and delivery from the Czech Republic

LR18XCF05ATC – Two-wire inductive proximity sensor

LR18XCF05ATC is a two-wire inductive proximity sensor from LANBAO, size M18. It detects metal objects without contact and switches in series with the load, so it needs only two wires — supply and signal share the same pair.

Key features

  • Sensing distance 5 mm – rated value for a standard steel target.
  • Output 2-wire, NC contact – normally closed – connects to a PLC digital input or a relay coil.
  • Supply 20–250 V AC.
  • Flush mounting.
  • Connection: cable 2 m.
  • Degree of protection IP67 – protection against dust and temporary immersion.

How an inductive sensor works

The coil in the sensing face generates a high-frequency magnetic field. When a metal object enters the field, it induces eddy currentsin its surface, which draw energy from the field and dampen it. As soon as the damping exceeds the set threshold, the evaluation circuit switches the output. All this happens without any contact, so the sensor has no mechanically wearing parts.

Inductive sensor principle: coil, high-frequency field and eddy currents in the metal target

High-frequency oscillation principle: coil field, eddy currents in the metal target and their damping effect.

Correction factor – why the range on aluminium differs from steel

The rated sensing distance applies to a standard steel target. For other metals it is reduced by a correction factor. Calculate the actual distance as the rated Sn multiplied by the material factor.

Steel St37 (standard target) 1.0
Cast iron 0.93 – 1.05
Aluminium 0.60 – 1.00
Stainless steel 0.65 – 0.75
Brass 0.35 – 0.50
Copper 0.25 – 0.45
Nickel 0.25 – 0.45
Example for this sensor: the rated Sn is 5 mm. On steel it therefore switches at 5 mm, on stainless steel at approximately 65 to 75 % of this value and on brass at only 35 to 50 %. If you detect non-ferrous metals, allow a margin or choose a model with correction factor 1.

Standard target and tolerance

According to the manufacturer's catalogue, the standard target is a square plate of St37 steel, 1 mm thick. The side length equals the larger of: the diameter of the sensing face, or three times the sensing distance. A smaller target means a shorter range. The sensing distance tolerance is ±10 %, so never set the working point exactly at the Sn limit.

Technical specifications LR18XCF05ATC

Order code LR18XCF05ATC
Manufacturer LANBAO
Size / housing M18
Sensing distance (Sn) 5 mm
Mounting / face design flush
Output type 2-wire
Contact function NC – normally closed
Supply voltage 20–250 V AC
Connection cable 2 m
Degree of protection IP67
Status indication LED
HS code (TARIC) 85365080
Country of origin CN

Wiring of LR18XCF05ATC by wire colours

Wire Colour Wiring
1 brown (BN) supply 20–250 V AC via the load connected in series
2 blue (BU) second supply pole

A two-wire AC sensor is connected in series with the load – a contactor, relay or AC PLC input. It has no separate signal wire.

Caution: according to the manufacturer's catalogue, two-wire AC sensors must not be connected in AND or OR logic and must not be in series with a mechanical contact.

The colour coding complies with IEC 60947-5-2. Always compare the actual pin and wire assignment with the diagram in the sensor datasheet (Downloads tab).

Two-wire connection of LR18XCF05ATC, load in series

Two-wire connection – the load is in series with the sensor.

Mounting and free space

The sensor has a flush sensing face, so it can be screwed into a metal structure right up to the face without affecting its function. The trade-off is a shorter sensing distance compared to the non-flush version.

Flush mounting of an inductive sensor

Flush mounting: the face may be level with the metal.

Mutual interference of sensors

Two sensors mounted close to each other may interfere with each other. If you need to sense at two adjacent points, keep the lateral spacing given in the sensor's dimension drawing, or offset the sensors so that their faces do not point into the same space.

Set the working distance to 70 to 80 % of the rated Sn, i.e. safely below 5 mm for this model. The tolerance is ±10 % and the distance also changes with temperature and supply voltage.

The same sensor with a different connection

The cable version is cheaper, but replacing the sensor requires pulling the entire cable. The connector variant can be replaced in a minute and is suitable where there is no time for downtime.

Typical applications

  • retrofitting existing installations where only a two-core cable is laid
  • replacing a mechanical limit switch without re-pulling the cabling
  • saving wires and terminals in the control cabinet on large machines
  • series connection with a relay, contactor or PLC input
  • simple signalling and monitoring circuits

How to choose and what to watch out for

  • Flush mounting: the sensor can be screwed into a metal structure right up to the face without affecting its function. Compared to the non-flush variant, however, it has a shorter sensing distance.
  • Two-wire connection: the sensor is connected in series with the load. Before use, check the residual current and voltage drop against the minimum values of the input you are connecting the sensor to.
  • NC contact (normally closed): the output is active at rest and opens on detection. It is used where a broken wire should cause the same reaction as a detection (safer logic).
  • Cable outlet: the cheaper variant, but replacing the sensor requires pulling the entire cable. If you need quick replacement, choose a model with a connector (suffix -E1 for M8, -E2 for M12).
  • Degree of protection IP67: protection against dust and temporary immersion. Not designed for permanent immersion or high-pressure washing – this requires IP69K.
  • Sensing distance 5 mm is the rated value for a standard steel target. For stainless steel, brass, aluminium or copper it is reduced by a reduction factor – if you detect non-ferrous metals, allow a margin or choose a model with correction factor 1.

NO or NC – and why it is not just a matter of convenience

NO (normally open) is an output that is active on detection. NC (normally closed) is active at rest and opens on detection. The difference is a safety one: with NC, a broken wire causes the same reaction as a detection, so the fault shows up immediately. With NO, a broken cable remains unnoticed until someone tries to switch.

This model has the contact NC – normally closed.

Similar models in the same series

Frequently asked questions

Does LR18XCF05ATC have a PNP or NPN output?

LR18XCF05ATC has a 2-wire output with an NC contact – normally closed. Check that your PLC input matches this output type.

What is the sensing distance of LR18XCF05ATC?

The sensing distance (Sn) is 5 mm. This is the rated value for a standard steel target; the range is shorter for non-ferrous metals.

How is LR18XCF05ATC connected?

LR18XCF05ATC is supplied with the connection: cable 2 m. The cable is part of the sensor; the other end is free for connection to a terminal block.

What is the difference compared to a three-wire PNP/NPN sensor?

A two-wire sensor is connected in series with the load and does not need a separate signal wire. It saves one core in the cable, but a residual current flows through it and it has a higher voltage drop, which must be taken into account with sensitive PLC inputs.

Are there other variants of LR18XCF05ATC?

In the same series we offer models with the same sensing distance and a different output type, contact function or connection: LR18XBF05DLC, LR18XBF05DLC-E2, LR18XBF05DLO, LR18XBF05DLO-5MPUR.

A detailed datasheet with a dimension drawing and wiring diagram can be found in the tab Downloads.

We supply LR18XCF05ATC from the Czech Republic with an invoice and technical support. Not sure which one to choose? Send us your application parameters and we will recommend a suitable model.

Do you have a sensor from another manufacturer on your machine – SICK, IFM, Balluff, Omron or Pepperl+Fuchs? Send us its order code and we will cross-reference it to the matching LANBAO model.

Technical parameters

Objednací kódLR18XCF05ATC
VýrobceLanbao
Sensing5mm
SizeM18
Mounting (flush/non-flush)Yes
ConnectionCable 2m PVC
Power supply20-250VAC
ContactNC
Output typeAC
Overall length61.5mm
Number of wires2

Ask about this product

Ask us about technical parameters, compatibility with your equipment, availability or a price for larger quantities. It helps if you tell us what application you need the product for — if it does not fit, we will recommend a more suitable type.

Kód k opsání. Pokud ho nepřečtete, klikněte na Načíst nový kód.
The question relates to product LR18XCF05ATC

By sending you agree to the processing of the data provided for the purpose of handling your question. We do not pass the data on to third parties.

Related products

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.