Phone +420 774 723 123 Cart · 0 · empty
LE82VF15DNC, LANBAO, rectangular inductive sensor, 8x8x40mm, Sn 1.5 mm, NPN, NC, cable 2 m

LE82VF15DNC, LANBAO, rectangular inductive sensor, 8x8x40mm, Sn 1.5 mm, NPN, NC, cable 2 m

Cat. no.: LE82VF15DNC
Manufacturer: Lanbao
On request
Our price excl. VAT
17,23 €
incl. VAT 21 %
20,84 €
Recycling fee 5-32-1 (0,041 €/kg) 0,00 €
Weight 0.04 kg
HS Code (Taric) 85365019
Country of origin CN

Description

Genuine LANBAO  ·  Free technical support  ·  Invoice and delivery from the Czech Republic

LE82VF15DNC – Inductive proximity sensor in a rectangular housing

LE82VF15DNC is an inductive proximity sensor in a rectangular housing from LANBAO, housing 8x8x40mm. It detects metal objects without contact using an electromagnetic field; the rectangular housing is screwed onto a flat surface, so it needs no threaded hole or nuts.

Key features

  • Sensing distance 1.5 mm – rated value for a standard steel target.
  • NPN output, NC contact – normally closed – connects to a PLC digital input or a relay coil.
  • Supply 10–30 V DC.
  • Flush mounting.
  • Connection: cable 2 m.
  • Degree of protection IP67 – protection against dust and temporary immersion.

How an inductive sensor works

The coil in the sensing face generates a high-frequency magnetic field. When a metal object enters the field, it induces eddy currentsin its surface, which draw energy from the field and dampen it. As soon as the damping exceeds the set threshold, the evaluation circuit switches the output. All this happens without any contact, so the sensor has no mechanically wearing parts.

Inductive sensor principle: coil, high-frequency field and eddy currents in the metal target

High-frequency oscillation principle: coil field, eddy currents in the metal target and their damping effect.

Correction factor – why the range on aluminium differs from steel

The rated sensing distance applies to a standard steel target. For other metals it is reduced by a correction factor. Calculate the actual distance as the rated Sn multiplied by the material factor.

Steel St37 (standard target) 1.0
Cast iron 0.93 – 1.05
Aluminium 0.60 – 1.00
Stainless steel 0.65 – 0.75
Brass 0.35 – 0.50
Copper 0.25 – 0.45
Nickel 0.25 – 0.45
Example for this sensor: the rated Sn is 1.5 mm. On steel it therefore switches at 1.5 mm, on stainless steel at approximately 65 to 75 % of this value and on brass at only 35 to 50 %. If you detect non-ferrous metals, allow a margin or choose a model with correction factor 1.

Standard target and tolerance

According to the manufacturer's catalogue, the standard target is a square plate of St37 steel, 1 mm thick. The side length equals the larger of: the diameter of the sensing face, or three times the sensing distance. A smaller target means a shorter range. The sensing distance tolerance is ±10 %, so never set the working point exactly at the Sn limit.

Technical specifications LE82VF15DNC

Order code LE82VF15DNC
Manufacturer LANBAO
Size / housing 8x8x40mm
Sensing distance (Sn) 1.5 mm
Mounting / face design flush
Output type NPN
Contact function NC – normally closed
Supply voltage 10–30 V DC
Connection cable 2 m
Degree of protection IP67
Status indication LED
HS code (TARIC) 85365019
Country of origin CN

Wiring of LE82VF15DNC by wire colours

Wire Colour Wiring
1 brown (BN) + supply (L+), 10–30 V DC
2 blue (BU) − supply (M / 0 V)
3 black (BK) NPN output, NC – closed at rest, opens on detection; switches the negative pole – for a sourcing-type PLC input

The colour coding complies with IEC 60947-5-2. Always compare the actual pin and wire assignment with the diagram in the sensor datasheet (Downloads tab).

Wiring diagram of LE82VF15DNC: brown plus, black output, blue minus

Three-wire cable wiring according to IEC 60947-5-2.

Mounting and free space

The sensor has a flush sensing face, so it can be screwed into a metal structure right up to the face without affecting its function. The trade-off is a shorter sensing distance compared to the non-flush version.

Flush mounting of an inductive sensor

Flush mounting: the face may be level with the metal.

Mutual interference of sensors

Two sensors mounted close to each other may interfere with each other. If you need to sense at two adjacent points, keep the lateral spacing given in the sensor's dimension drawing, or offset the sensors so that their faces do not point into the same space.

Set the working distance to 70 to 80 % of the rated Sn, i.e. safely below 1.5 mm for this model. The tolerance is ±10 % and the distance also changes with temperature and supply voltage.

The same sensor with a different connection

The cable version is cheaper, but replacing the sensor requires pulling the entire cable. The connector variant can be replaced in a minute and is suitable where there is no time for downtime.

Typical applications

  • mounting on a flat frame or profile without drilling a threaded hole
  • position detection in narrow and confined machine spaces
  • monitoring stops and end positions of handling devices
  • checking the presence of a metal part in a tray or magazine
  • applications where sensing from the side rather than along the axis is needed

How to choose and what to watch out for

  • Flush mounting: the sensor can be screwed into a metal structure right up to the face without affecting its function. Compared to the non-flush variant, however, it has a shorter sensing distance.
  • NPN output (switches minus) is used mainly in Asian equipment and selected PLCs. For standard European inputs, the PNP variant is usually more suitable.
  • NC contact (normally closed): the output is active at rest and opens on detection. It is used where a broken wire should cause the same reaction as a detection (safer logic).
  • Cable outlet: the cheaper variant, but replacing the sensor requires pulling the entire cable. If you need quick replacement, choose a model with a connector (suffix -E1 for M8, -E2 for M12).
  • Degree of protection IP67: protection against dust and temporary immersion. Not designed for permanent immersion or high-pressure washing – this requires IP69K.
  • Sensing distance 1.5 mm is the rated value for a standard steel target. For stainless steel, brass, aluminium or copper it is reduced by a reduction factor – if you detect non-ferrous metals, allow a margin or choose a model with correction factor 1.

PNP or NPN – and what happens if you mix them up

PNP switches the positive pole, so it sends plus to the PLC input. It is the European standard and matches standard digital inputs. NPN switches minus and is used mainly in Asian equipment. If mixed up, the sensor either does not switch at all or reports a permanently active state — it usually will not be damaged, but it will not work.

This model has a NPN. If you need PNP, a variant with the same sensing distance is available — contact us and we will recommend the code.

NO or NC – and why it is not just a matter of convenience

NO (normally open) is an output that is active on detection. NC (normally closed) is active at rest and opens on detection. The difference is a safety one: with NC, a broken wire causes the same reaction as a detection, so the fault shows up immediately. With NO, a broken cable remains unnoticed until someone tries to switch.

This model has the contact NC – normally closed.

Similar models in the same series

Frequently asked questions

Does LE82VF15DNC have a PNP or NPN output?

LE82VF15DNC has an NPN output with an NC contact – normally closed. Check that your PLC input matches this output type.

What is the sensing distance of LE82VF15DNC?

The sensing distance (Sn) is 1.5 mm. This is the rated value for a standard steel target; the range is shorter for non-ferrous metals.

How is LE82VF15DNC connected?

LE82VF15DNC is supplied with the connection: cable 2 m. The cable is part of the sensor; the other end is free for connection to a terminal block.

How is LE82VF15DNC wired by wire colours?

Brown wire to supply plus, blue to minus, and black is the signal output going to the PLC input or relay coil. The coding complies with IEC 60947-5-2.

Why choose a rectangular housing instead of a cylindrical M12/M18?

A rectangular housing is screwed onto a flat surface with two screws and does not require a threaded hole with nuts. It is suitable where there is no room for a cylindrical body or where sensing from the side is needed.

A detailed datasheet with a dimension drawing and wiring diagram can be found in the tab Downloads.

We supply LE82VF15DNC from the Czech Republic with an invoice and technical support. Not sure which one to choose? Send us your application parameters and we will recommend a suitable model.

Do you have a sensor from another manufacturer on your machine – SICK, IFM, Balluff, Omron or Pepperl+Fuchs? Send us its order code and we will cross-reference it to the matching LANBAO model.

Technical parameters

Objednací kódLE82VF15DNC
VýrobceLanbao

Downloads

Ask about this product

Ask us about technical parameters, compatibility with your equipment, availability or a price for larger quantities. It helps if you tell us what application you need the product for — if it does not fit, we will recommend a more suitable type.

Kód k opsání. Pokud ho nepřečtete, klikněte na Načíst nový kód.
The question relates to product LE82VF15DNC

By sending you agree to the processing of the data provided for the purpose of handling your question. We do not pass the data on to third parties.

Related products

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.