Electromagnetic Relays

Electromagnetic industrial relays, sockets and accessories for switching signals and smaller loads in control cabinets. Choose by coil voltage (AC/DC), number and rating of contacts and socket type.

Alkategóriák

Szűrők
Találatok 33 termék
TIPPÜNK RAKTÁRON

R4N-2014-23-5230-WT, RELPOL, industrial relay 4× changeover contact, coil 230VAC, 6A AC-1

Kat. szám: R4N-2014-23-5230-WT

R4N-2014-23-5230-WT, RELPOL: industrial relay with four changeover contacts 4CO and a 230VAC coil; contact current AC-1 6A.

Raktáron 5 db vagy több
4,59 €
ÁFA nélkül · 5,55 € ÁFÁ-val
RAKTÁRON

RS1P11G1, EMAS, socket for 11-pin relay

Kat. szám: RS1P11G1

RS1P11G1 EMAS – socket for 11-pin relay. Exact technical data for selecting the relay socket type.

Raktáron 5 db vagy több
4,92 €
ÁFA nélkül · 5,95 € ÁFÁ-val
−3 % RAKTÁRON

PI6W-1P, RELPOL, screw socket for relay RM699BV, 1CO, width 6.2mm, DIN 35mm

Kat. szám: PI6W-1P

PI6W-1P, RELPOL: feed-through socket with screw terminals for RM699BV and RSR30, width 6.2mm, DIN rail 35mm.

Raktáron 5 db vagy több
9,13 € 9,42 €
ÁFA nélkül · 11,05 € ÁFÁ-val
TIPPÜNK RAKTÁRON

RE1P11DC024, EMAS, power relay 3CO, 11 pins, coil 24 V DC, contacts 10 A / 250 V AC, 3CO / 3 changeover

Kat. szám: RE1P11DC024

RE1P11DC024 EMAS – power relay 3CO, 11 pins, coil 24 V DC, contacts 10 A / 250 V AC, 3CO / 3 changeover. Exact technical data for selecting the electromagnetic relay type.

Raktáron 5 db vagy több
10,24 €
ÁFA nélkül · 12,39 € ÁFÁ-val
TIPPÜNK RAKTÁRON

RE1P11AC220, EMAS, electromagnetic relay, 3 contacts(11pin), 10A, coil 230VAC, 230 V AC, 10 A

Kat. szám: RE1P11AC220

RE1P11AC220 EMAS – electromagnetic relay, 3 contacts(11pin), 10A, coil 230VAC, 230 V AC, 10 A. Key data: RS1P11G1. Exact technical data for selecting the electromagnetic relay type.

Raktáron 2 ks
10,24 €
ÁFA nélkül · 12,39 € ÁFÁ-val
TIPPÜNK RAKTÁRON

PIR6W-1P-230VAC/DC, RELPOL, industrial relay, 230 V AC, 11, 12, 14

Kat. szám: PIR6W-1P-230VAC/DC

PIR6W-1P-230VAC/DC RELPOL – industrial relay, 230 V AC, 11, 12, 14. Exact technical data for selecting the electromagnetic relay type.

Raktáron 5 db vagy több
11,06 €
ÁFA nélkül · 13,38 € ÁFÁ-val
TIPPÜNK RAKTÁRON

PIR6W-1P-24VAC/DC, RELPOL, slim interface relay 24VAC/DC, 1CO, 6A, 6.2mm

Kat. szám: PIR6W-1P-24VAC/DC

PIR6W-1P-24VAC/DC, RELPOL, slim interface relay 24VAC/DC, 1CO, 6A, 6.2mm. Relpol PIR6W-1P-24VAC/DC is an interface relay with a width of 6.2mm designed for signal and control circuits.

Raktáron 5 db vagy több
11,06 €
ÁFA nélkül · 13,38 € ÁFÁ-val

Az árak tartalmazzák az újrahasznosítási díjat.

Electromagnetic relays

Choose an electromagnetic relay as the interface between a command and a specific switched circuit. First determine whether you are designing a new control cabinet or replacing an existing part. For a new assembly, you need an electrical brief and installation space. For a replacement, also compare the complete order code, the socket version and the documentation of the original wiring.

Deciding: separate part or assembly

The range includes the RM84, RM87N and R4N families as well as EMAS relays. For the switching element itself, open Relay, for its base Sockets and for add-ons Accessories. The guide Complete relays with socket explains the selection of the assembly. The breakdown helps prepare a parts list without automatically assuming what the pack contains.

For each required contact, write down its specific task. One may pass a command, another the state to the higher-level control system. The number of contacts then follows from the list of functions; do not start with the housing size. For contacts that are to change state simultaneously, also record the permissible time differences for the application.

Principle of the coil and contact circuit

OMRON explains a common monostable relay by the movement of the armature caused by the coil and the return of the spring after de-energisation. NO denotes a contact open in the rest state, NC a closed one. A changeover contact connects the common terminal alternately to these two branches.

RELPOL data sheet RM84 separates the loads AC1, AC15, DC1 and DC13. Do not transfer resistive load capacity to a solenoid. Likewise, do not confuse mechanical endurance with electrical endurance under a specific load.

When comparing two candidates, mark the documented value or missing documentation for each requirement. An empty row is a reason to complete the documentation before selection.

Author's model example: operating frequency

A model machine performs six complete on/off cycles per minute. Over eight hours of work, this is 6 × 60 × 8 = 2 880 cycles per day, and over 250 days 720 000 cycles per year. This is our own operating brief, not a parameter of the relay offered or a prediction of its service life.

Transfer the result to the requirement for verifying electrical endurance. Separately note manual adjustment and repeated start-ups that are absent from the normal cycle. If these activities are frequent, calculate their contribution from real operation. An exact number of cycles is more useful than a vague description of “occasional switching”.

Mounting: legibility and replaceability

In the rail layout, draw the position of the labels, supply wires and retaining clip. Verify that the relay can be identified even after the wiring is complete. Also enter the add-on module in the bill of materials if it is part of the design. A later replacement should be based on this assembly, not just on the cover colour or the number of pins.

Diagnosing irregular operation

In the case of occasional failure to pick up, record the relationship with the starting of other loads and with the heating of the control cabinet. OMRON's guidance on coils points out the influence of temperature and actual voltage on function. A professional check must work with the limits of the chosen type, not just with the voltage written on the power supply.

FAQ

Do parallel contacts automatically increase the switched current?

No. OMRON explains the uneven moment of contact closure; one of them may briefly carry the entire load. Do not add currents without explicit documentation from the manufacturer.

Are more contacts proof of a safety design?

No. A safety function requires a documented design and assessment of the entire function. The number of NO and NC alone does not allow such a conclusion.

Sütik ezen a weboldalon

A technikai sütikre a kosár és a rendelés működéséhez van szükség — ezeket mindig használjuk. Az analitikai sütik megmutatják, mely oldalakat keresik az emberek és hol akadnak el, és segítenek javítani a webáruházat. Ezeket csak akkor használjuk, ha engedélyezi. Bővebben: adatkezelési tájékoztatóban.