UR18-CM1DI-E2, LANBAO, ultrasonic distance sensor 60–1000mm, 4-20mA, Connector M12/4
UR18-CM1DI-E2 LANBAO – ultrasonic sensor, 60–1000mm, Connector M12. Industrial product for automation, measurement and control.
Árfolyam 24,47 Kč / 1 EUR. Az árak tájékoztató jellegűek, a számlázás cseh koronában történik.
Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.
UR18-CM1DI-E2 LANBAO – ultrasonic sensor, 60–1000mm, Connector M12. Industrial product for automation, measurement and control.
UM18-21212C211 (6066176), SICK – ultrasonic sensor, 65–350mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21212C212 (6066177), SICK – ultrasonic sensor, 65–350mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21212D211 (6066178), SICK – ultrasonic sensor, 65–350mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21212D212 (6066179), SICK – ultrasonic sensor, 65–350mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21212E211 (6068443), SICK – ultrasonic sensor, 65–350mm, PNP/NPN, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21212E212 (6068444), SICK – ultrasonic sensor, 65–350mm, PNP/NPN, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-212161101 (6048416), SICK – ultrasonic sensor, 65–350mm, PNP, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-212161102 (6048417), SICK – ultrasonic sensor, 65–350mm, PNP, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-212165101 (6048418), SICK – ultrasonic sensor, 65–350mm, NPN, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-212165102 (6048419), SICK – ultrasonic sensor, 65–350mm, NPN, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-212166101 (6072879), SICK – ultrasonic sensor, 65–350mm, 4–20mA, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-212166102 (6072880), SICK – ultrasonic sensor, 65–350mm, 4–20mA, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-212167101 (6072881), SICK – ultrasonic sensor, 65–350mm, 0–10V, 15–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-212167102 (6072882), SICK – ultrasonic sensor, 65–350mm, 0–10V, 15–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UM18-217126111 (6048386), SICK – ultrasonic sensor, 20–150mm, 4–20mA, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-217126112 (6048387), SICK – ultrasonic sensor, 20–150mm, 4–20mA, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-217127111 (6048388), SICK – ultrasonic sensor, 20–150mm, 0–10V, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-217127112 (6048389), SICK – ultrasonic sensor, 20–150mm, 0–10V, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21712B211 (6066162), SICK – ultrasonic sensor, 20–150mm, PNP/NPN, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21712B212 (6066163), SICK – ultrasonic sensor, 20–150mm, PNP/NPN, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21712C211 (6066164), SICK – ultrasonic sensor, 20–150mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21712C212 (6066165), SICK – ultrasonic sensor, 20–150mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21712D211 (6066166), SICK – ultrasonic sensor, 20–150mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UM18-21712D212 (6066167), SICK – ultrasonic sensor, 20–150mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
Az árak tartalmazzák az újrahasznosítási díjat.
Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.
First determine the nearest and farthest position of the object. The entire working path must lie within the usable measuring range of the specific sensor. With a conventional diffuse-mode version, leave space in front of the face for the blind zone. Teach-in sets the evaluation limits; it does not remove this physical limit.
For presence detection or reaching a limit, choose the appropriate PNP or NPN switching output. For continuous distance, verify the analogue signal, for example 4–20 mA or 0–10 V, or the digital interface stated by the manufacturer. NO/NC function, hysteresis and window mode describe the evaluation method and are not a substitute for data on the electrical output.
Cylindrical versions are used to check distance, stack height or roll diameter. Colour and transparency are not the main criterion for ultrasound; the return of the sound echo is decisive. Orient a smooth surface according to the manufacturer's instructions; an inclined or sound-absorbing target requires a practical test.
View LANBAO UR18-CM1DI-E2 as a specific example from the range. Verify the parameters of other variants separately.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: Ultrasonic measuring principle – microsonic · Mounting ultrasonic sensors – microsonic.
The thread determines the mechanical design. Compare the range, blind zone and detection diagram in the datasheet of the specific model. When replacing, also check the body length and the space behind the connector.
A switching output transmits a state when a set limit is reached. For a continuous value, you need a corresponding analogue signal or a digital interface supported by both the sensor and the control system. Teach-in sets limits within the usable range.
A technikai sütikre a kosár és a rendelés működéséhez van szükség — ezeket mindig használjuk. Az analitikai sütik megmutatják, mely oldalakat keresik az emberek és hol akadnak el, és segítenek javítani a webáruházat. Ezeket csak akkor használjuk, ha engedélyezi. Bővebben: adatkezelési tájékoztatóban.
Válassza ki, mely sütiket használhatunk. A választást bármikor módosíthatja.
Megőrzik a kosár tartalmát, a bejelentkezést és a kiválasztott nyelvet, és védik az űrlapokat a visszaélésektől. Nélkülük a rendelés nem fejezhető be, ezért hozzájárulás nélkül is használjuk őket.
A Google Analytics összesített formában mutatja meg a weboldal látogatottságát és a felhasználói viselkedést. Ebből tudjuk meg, mely oldalak nem működnek jól. Ezek alapján senkit nem azonosítunk.