PSA020AK131S, EMAS, main cam switch 0-1, 400V AC, 20 A, IP54

N.º cat.: PSA020AK131S

PSA020AK131S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
8,07 €
sin IVA · 9,76 € con IVA
NUESTRO CONSEJO EN STOCK

PSA016AK331S, EMAS, main switch standard 0-1, angle 60 °, number of poles 3, current 16A

N.º cat.: PSA016AK331S

PSA016AK331S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
11,58 €
sin IVA · 14,01 € con IVA
NUESTRO CONSEJO EN STOCK

PSA025AK131S, EMAS, main cam switch 0-1, 400V AC, 25A, IP54

N.º cat.: PSA025AK131S

PSA025AK131S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
11,98 €
sin IVA · 14,50 € con IVA
NUESTRO CONSEJO EN STOCK

PSA020AK331S, EMAS, main switch standard 0-1, angle 60 °, number of poles 3, current 20A

N.º cat.: PSA020AK331S

PSA020AK331S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
12,70 €
sin IVA · 15,37 € con IVA
NUESTRO CONSEJO EN STOCK

PSA032AK131S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 1, current 32A

N.º cat.: PSA032AK131S

PSA032AK131S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
13,38 €
sin IVA · 16,19 € con IVA
NUESTRO CONSEJO EN STOCK

PSA025AK231S, EMAS, main switch standard 0-1, angle 60 °, number of poles 2, current 25A

N.º cat.: PSA025AK231S

PSA025AK231S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
15,14 €
sin IVA · 18,31 € con IVA
NUESTRO CONSEJO EN STOCK

PSA025AK331S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 3, current 25A

N.º cat.: PSA025AK331S

PSA025AK331S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
18,33 €
sin IVA · 22,18 € con IVA
NUESTRO CONSEJO EN STOCK

PSA032AK331S, EMAS, main switch standard 0-1, angle 60 °, number of poles 3, current 32A

N.º cat.: PSA032AK331S

PSA032AK331S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 2 ks
21,27 €
sin IVA · 25,73 € con IVA
NUESTRO CONSEJO EN STOCK

PSA040AK131S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 1, current 40A

N.º cat.: PSA040AK131S

PSA040AK131S EMAS - main cam switch 0-1, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
21,49 €
sin IVA · 26,00 € con IVA
NUESTRO CONSEJO EN STOCK

PSA040AK331S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 3, current 40A

N.º cat.: PSA040AK331S

PSA040AK331S EMAS - main cam switch 0-1, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

En stock 5 uds. o más
29,64 €
sin IVA · 35,87 € con IVA
NUESTRO CONSEJO

PSA010AK131S, EMAS, main switch standard 0-1, angle 60 °, number of poles 1, current 10A

N.º cat.: PSA010AK131S

PSA010AK131S EMAS - main cam switch 0-1, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
7,30 €
sin IVA · 8,83 € con IVA
NUESTRO CONSEJO

PSA016AK131S, EMAS, main cam switch 0-1, 400V AC, 16 A, IP54

N.º cat.: PSA016AK131S

PSA016AK131S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
7,53 €
sin IVA · 9,11 € con IVA
NUESTRO CONSEJO

PSA010AK231S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 2, current 10A

N.º cat.: PSA010AK231S

PSA010AK231S EMAS - main cam switch 0-1, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
8,97 €
sin IVA · 10,85 € con IVA
NUESTRO CONSEJO

PSA016AK231S, EMAS, main cam switch 0-1, 400V AC, 16 A, IP54

N.º cat.: PSA016AK231S

PSA016AK231S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, assembly and selection of the correct variant.

Bajo consulta
9,28 €
sin IVA · 11,23 € con IVA
NUESTRO CONSEJO

PSA020AK231S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 2, current 20A

N.º cat.: PSA020AK231S

PSA020AK231S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
9,96 €
sin IVA · 12,05 € con IVA
NUESTRO CONSEJO

PSA010AK331S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 3, current 10A

N.º cat.: PSA010AK331S

PSA010AK331S EMAS - main cam switch 0-1, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
11,26 €
sin IVA · 13,63 € con IVA
NUESTRO CONSEJO

PSA032AK231S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 2, current 32A

N.º cat.: PSA032AK231S

PSA032AK231S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
16,22 €
sin IVA · 19,62 € con IVA
NUESTRO CONSEJO

PSA050AK131S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 1, current 50A

N.º cat.: PSA050AK131S

PSA050AK131S EMAS - main cam switch 0-1, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
24,42 €
sin IVA · 29,55 € con IVA
NUESTRO CONSEJO

PSA040AK231S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 2, current 40A

N.º cat.: PSA040AK231S

PSA040AK231S EMAS - main cam switch 0-1, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
25,45 €
sin IVA · 30,79 € con IVA
NUESTRO CONSEJO

PSA063AK131S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 1, current 63A

N.º cat.: PSA063AK131S

PSA063AK131S EMAS - main cam switch 0-1, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

Bajo consulta
25,59 €
sin IVA · 30,97 € con IVA

Los precios incluyen la tasa de reciclaje.

On / Off Switches 60 °

Splice On/Off switches at 60° for a clear switch between off and on operational states. For a two-way switch, the specification changes: do not choose A or B, but determine which electrical paths to close in position 1 and open in position 0. The required number of poles depends on the circuit, not on the number of these positions.

Specific offer of the PSA series

For example, TECHNOLINE presents EMAS PSA010AK131S, PSA016AK131S and PSA020AK131S. Manufacturer for PSA016AK131S confirms one pole path, marking 0-1, angle 60 ° and forehead 48 × 48 mm. His Ie 16 A is given in category AC21A. This model therefore represents a specific single-pole design, not a universal solution of each supply.

What one handle really has to control

Before selecting, determine all paths that change state together. Current mechanical control does not mean that currents from different poles simply add up to a single allowed value. Each path has its load, and the entire device has its operational conditions. For a combination of several functions, also verify the actual contact program.

Position 0 is the operational state indicator, not proof of suitability for insulation. If the project requires a main disconnection function, handle it explicitly according to the documentation. Even transitioning to a branch On / Off Safety switches 90 ° is not an automatic solution to such a requirement without checking the parameters.

Model example of resistance load

To explain the current, choose two ideal resistive loads, each with 600 W at 230 V. Each draws approximately 600/230 = 2.61 A. The total power is 1,200 W. If considering a common path carrying both loads, it draws approximately 5.22 A; a single path for one load still carries only 2.61 A. The specific circuit structure determines this.

This specific example does not determine the wiring of fuses or the recommended number of poles. It calculates an ideal steady-state load, not a possible startup event or device heating. Results cannot be transferred to a motor of the same power. For a motor, specify the starting value and usage conditions; a simple ratio of watts and volts does not create it.

Selection of design and assembly space

When swapping, keep function 0–1 but compare the full code, usage category, voltage, and mechanical arrangement. A larger current model does not necessarily have the same depth or mounting. Add the panel part dimensions and access to connection points with a diagram.

For separate installation choose the corresponding box and other accessoriesThe enclosure of the entire assembly depends on the installation of the controller and cable inputs. For a switch, compare the marked position with the actual contact state and the machine documentation. Installing on mains voltage is not a task for trial installation based on a similar photo; it should be done by a professional.

Frequently asked questions

Is the two-position switch automatically two-pole?

No. Two 0 and 1 positions determine the grip states. The number of poles is a separate electrical figure.

Is a higher current enough if the type of appliance changes?

Not always. Another load may require a different category or special switching conditions, even if it has a smaller steady-state consumption.

When to select a switch instead of a switch?

When the actuator has to choose between multiple functions, not just allow one. The distribution of programs and basic dimensioning rules describes the overview Vacuum cleaners.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.