Cables with Connector

Cables with M8 and M12 connectors for connecting sensors and actuators. You will find straight and angled connectors, various lengths and pin counts, with or without LED indication and PVC or PUR sheaths. Choose by sensor connector, pin count, length and environment.

Filtros
Encontrado 191 productos

QE12-W5G2-U, LANBAO, Sensor cable M12/5pin, Angled, Male, length 2m, PUR

N.º cat.: QE12-W5G2-U

QE12-W5G2-U LANBAO – connection cable with sensor connector, M12, 5, angled, male, 2 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
10,65 €
sin IVA · 12,89 € con IVA

RKC4.4T-2/TXL, CONNECTION CABLE, female, 4pin, M12 x 1, PUR cable length 5m, TURCK

N.º cat.: RKC4.4T-2/TXL

RKC4.4T-2/TXL CONNECTION CABLE – connection cable with sensor connector, M12, 4, straight, female, 2.0 m, PUR, black. Connection cable for industrial sensors and automation equipment.

Bajo consulta
10,73 €
sin IVA · 12,98 € con IVA
NUESTRO CONSEJO

BCC02M9, SENSOR CABLE, BCC M313-0000-10-001-PX0334-050, Balluff

N.º cat.: BCC02M9

BCC02M9 SENSOR CABLE – connection cable with sensor connector, M8, straight, female, 5 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
10,82 €
sin IVA · 13,09 € con IVA

PKG3M-5/TXL, CONNECTION CABLE, 6625551, Turck

N.º cat.: PKG3M-5/TXL

PKG3M-5/TXL CONNECTION CABLE – connection cable with sensor connector, M8, 3, straight, female, 5.0 m, PUR, black. Connection cable for industrial sensors and automation equipment.

Bajo consulta
11,26 €
sin IVA · 13,63 € con IVA
NUESTRO CONSEJO

BCC02NE, SENSOR CABLE M8/4PINY, angled, female, length 5m, PUR, BCC M324-0000-10-003-PX0434-050, Balluff

N.º cat.: BCC02NE

BCC02NE SENSOR CABLE M8/4PINY – connection cable with sensor connector, M8, 4, angled, female, 5 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
12,70 €
sin IVA · 15,36 € con IVA

QE12-N5F10, LANBAO, sensor cable M12/5-pin, Straight, Female, length 10m, PVC

N.º cat.: QE12-N5F10

QE12-N5F10 LANBAO – connection cable with sensor connector, M12, 5, angled, female, 10 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
12,71 €
sin IVA · 15,38 € con IVA

QE12-N5G10, LANBAO, sensor cable M12/5-pin, Angled, Female, length 10m, PVC

N.º cat.: QE12-N5G10

QE12-N5G10 LANBAO – connection cable with sensor connector, M12, 5, angled, female, 10 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
12,71 €
sin IVA · 15,38 € con IVA

RKC4.4T-5/TXL, CONNECTION CABLE, 6625504, TURCK

N.º cat.: RKC4.4T-5/TXL

RKC4.4T-5/TXL CONNECTION CABLE – connection cable with sensor connector, M12, 4, straight, female, 5.0 m, PUR, black. Connection cable for industrial sensors and automation equipment.

Bajo consulta
13,60 €
sin IVA · 16,46 € con IVA

NEBA-M8W4-U-5-N-LE4, CONNECTION CABLE, 8078234, Festo

N.º cat.: NEBA-M8W4-U-5-N-LE4

NEBA-M8W4-U-5-N-LE4 CONNECTION CABLE – connection cable with sensor connector, 5 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
14,54 €
sin IVA · 17,59 € con IVA

QE12-N5F10-U, LANBAO, sensor cable M12/5-pin, Straight, Female, length 10m, PUR

N.º cat.: QE12-N5F10-U

QE12-N5F10-U LANBAO – connection cable with sensor connector, M12, 5, angled, female, 10 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
16,60 €
sin IVA · 20,08 € con IVA
NUESTRO CONSEJO

EVC080, CONNECTION CABLE WITH PLUG, ASTAH040MSS0005H04, IFM

N.º cat.: EVC080

EVC080 CONNECTION CABLE WITH PLUG – connection cable with sensor connector, angled, angled, 5 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
17,81 €
sin IVA · 21,55 € con IVA

QE12-N5F20, LANBAO, sensor cable M12/5 pins, straight, female, 20 m, PVC

N.º cat.: QE12-N5F20

QE12-N5F20 LANBAO – connection cable with sensor connector, M12, 5, angled, straight, female – internal thread, 20 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
28,28 €
sin IVA · 34,22 € con IVA

YG2A14-100UB3XLEAX, CABLE WITH CONNECTOR, 2095768, Sick

N.º cat.: YG2A14-100UB3XLEAX

YG2A14-100UB3XLEAX CABLE WITH CONNECTOR – connection cable with sensor connector, M12, angled, male, 10 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
36,66 €
sin IVA · 44,35 € con IVA

BCC06UM, BALLUFF, cable with connector M12/12 pins, Straight, Female, length 10m, PVC, BCC M41C-0000-1A-049-PX0C25-100

N.º cat.: BCC06UM

BCC06UM BALLUFF – connection cable with sensor connector, M12, straight, female, 10 m, PVC. Connection cable for industrial sensors and automation equipment.

Bajo consulta
65,97 €
sin IVA · 79,83 € con IVA

YN2D24-100PN1XLEAX, CABLE WITH CONNECTOR, 2106176, Sick

N.º cat.: YN2D24-100PN1XLEAX

YN2D24-100PN1XLEAX CABLE WITH CONNECTOR – connection cable with sensor connector, M12, angled, male, 10 m, PUR. Connection cable for industrial sensors and automation equipment.

Bajo consulta
91,53 €
sin IVA · 110,75 € con IVA

Los precios incluyen la tasa de reciclaje.

Cables with Connector

Choose a ready-made cable according to the complete order designation. The public range includes, for example, Lanbao QE12-N4F2 and a version with indication QE12-N4G2-P. Different terminations and built-in indication matter for both mounting and diagnostics. Before choosing a replacement, copy the label of the original cable and find out whether the problem arises directly at the connector, in a moving section or at the end of the line.

Decision: outlet direction and actual route length

First check the mating part, coding, number of contacts and their assignment. Then decide between a straight and angled version. For an angled connector, draw the direction in which the cable leaves after connection: the sensor's position may point the outlet towards the frame. For a straight version, allow for space behind the connector. Also check the other end of the cable; the choice is different for free wires to terminals and for an interconnection assembly.

For purchasing, prepare two separate pieces of information: the required length and the type of movement. Excess cable stored next to a fixed frame is a different situation from a loop moving with a carriage. Do not use the PVC or PUR jacket material alone as proof of the permitted number of cycles. If confirmation for the given dynamics is missing, the selection for a moving application is not complete.

Principle: LED indication belongs to the electrical design

Lanbao datasheet QE12-N4xx-P describes a PNP version with green power indication and yellow activity indication. The table distinguishes separately the material of the connector body and the cable material. So do not transfer the body data to the jacket. The sheet also shows the assignment of contacts to wire colours; before wiring, compare it with the pin functions of the specific sensor.

Assess a cable with indication as an electrical assembly with its own limitations. Verify a requirement for an analogue signal or IO-Link communication explicitly for the chosen version. If the documentation does not confirm such use, mechanical compatibility alone is not enough to recommend it. For an ordinary interconnection cable, check the continuity of both ends, not just that they look the same.

Mounting: a cable without strain on the termination

Before mounting, compare the connection drawing with the actual wire markings. First lay the cable loosely along the route and check the end positions of the moving part. Then determine the fixing points. Leave handling space for the connector so that future replacement does not require pulling on the cable. Make the connection, sealing and tightening according to the instructions of the selected assembly; a universal torque for all connectors cannot be specified here.

Author's model example, not a product parameter

The designed fixed route measures 3.1 m and two service loops are 0.2 m each. The total is 3.5 m. A cable 3 m long will therefore not cover this particular route. For a longer candidate, storage of the excess must also be designed and bends verified. The calculation does not determine the minimum permitted radius or the service life of any cable offered.

Diagnostics: look for a connection with movement

If a dropout occurs only in a certain position of the mechanism, record it and inspect the corresponding part of the route with the machine secured. For comparison, use a cable with known wiring. A check with a sensor tester can separate the sensor test from a line problem; afterwards also verify the original wiring to the control system.

FAQ

Does a lit LED prove a correct signal in the PLC?

Local indication alone does not confirm the whole transmission. Compare it with the state of the corresponding input and the expected function.

What if the required length of a ready-made cable does not fit?

Consider a bulk cable and a suitable field-wireable connector. However, the assembly requires its own check of termination and compatibility.

Cookies en este sitio web

Necesitamos las cookies técnicas para que funcionen el carrito y el pedido — se usan siempre. Las cookies analíticas nos muestran qué páginas buscan las personas y dónde se pierden, y nos ayudan a mejorar la tienda. Solo las usaremos si nos lo permites. Más información en la política de tratamiento de datos.