PSA020AK131S, EMAS, main cam switch 0-1, 400V AC, 20 A, IP54
PSA020AK131S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
Árfolyam 24,43 Kč / 1 EUR. Az árak tájékoztató jellegűek, a számlázás cseh koronában történik.
EMAS ON/OFF 0–1 cam switches with 60° switching angle. Choose by current and number of poles.
PSA020AK131S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016AK331S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025AK131S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020AK331S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA032AK131S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025AK231S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025AK331S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA032AK331S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA040AK131S EMAS - main cam switch 0-1, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA040AK331S EMAS - main cam switch 0-1, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010AK131S EMAS - main cam switch 0-1, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016AK131S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010AK231S EMAS - main cam switch 0-1, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016AK231S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, assembly and selection of the correct variant.
PSA020AK231S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010AK331S EMAS - main cam switch 0-1, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010AK831S EMAS - main cam switch 0-1, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016AK831S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020AK831S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA032AK231S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025AK831S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA032AK831S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, assembly and selection of the correct variant.
PSA050AK131S EMAS - main cam switch 0-1, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA040AK231S EMAS - main cam switch 0-1, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA063AK131S EMAS - main cam switch 0-1, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.
Az árak tartalmazzák az újrahasznosítási díjat.
Splice On/Off switches at 60° for a clear switch between off and on operational states. For a two-way switch, the specification changes: do not choose A or B, but determine which electrical paths to close in position 1 and open in position 0. The required number of poles depends on the circuit, not on the number of these positions.
For example, TECHNOLINE presents EMAS PSA010AK131S, PSA016AK131S and PSA020AK131S. Manufacturer for PSA016AK131S confirms one pole path, marking 0-1, angle 60 ° and forehead 48 × 48 mm. His Ie 16 A is given in category AC21A. This model therefore represents a specific single-pole design, not a universal solution of each supply.
Before selecting, determine all paths that change state together. Current mechanical control does not mean that currents from different poles simply add up to a single allowed value. Each path has its load, and the entire device has its operational conditions. For a combination of several functions, also verify the actual contact program.
Position 0 is the operational state indicator, not proof of suitability for insulation. If the project requires a main disconnection function, handle it explicitly according to the documentation. Even transitioning to a branch On / Off Safety switches 90 ° is not an automatic solution to such a requirement without checking the parameters.
To explain the current, choose two ideal resistive loads, each with 600 W at 230 V. Each draws approximately 600/230 = 2.61 A. The total power is 1,200 W. If considering a common path carrying both loads, it draws approximately 5.22 A; a single path for one load still carries only 2.61 A. The specific circuit structure determines this.
This specific example does not determine the wiring of fuses or the recommended number of poles. It calculates an ideal steady-state load, not a possible startup event or device heating. Results cannot be transferred to a motor of the same power. For a motor, specify the starting value and usage conditions; a simple ratio of watts and volts does not create it.
When swapping, keep function 0–1 but compare the full code, usage category, voltage, and mechanical arrangement. A larger current model does not necessarily have the same depth or mounting. Add the panel part dimensions and access to connection points with a diagram.
For separate installation choose the corresponding box and other accessoriesThe enclosure of the entire assembly depends on the installation of the controller and cable inputs. For a switch, compare the marked position with the actual contact state and the machine documentation. Installing on mains voltage is not a task for trial installation based on a similar photo; it should be done by a professional.
No. Two 0 and 1 positions determine the grip states. The number of poles is a separate electrical figure.
Not always. Another load may require a different category or special switching conditions, even if it has a smaller steady-state consumption.
When the actuator has to choose between multiple functions, not just allow one. The distribution of programs and basic dimensioning rules describes the overview Vacuum cleaners.
A technikai sütikre a kosár és a rendelés működéséhez van szükség — ezeket mindig használjuk. Az analitikai sütik megmutatják, mely oldalakat keresik az emberek és hol akadnak el, és segítenek javítani a webáruházat. Ezeket csak akkor használjuk, ha engedélyezi. Bővebben: adatkezelési tájékoztatóban.
Válassza ki, mely sütiket használhatunk. A választást bármikor módosíthatja.
Megőrzik a kosár tartalmát, a bejelentkezést és a kiválasztott nyelvet, és védik az űrlapokat a visszaélésektől. Nélkülük a rendelés nem fejezhető be, ezért hozzájárulás nélkül is használjuk őket.
A Google Analytics összesített formában mutatja meg a weboldal látogatottságát és a felhasználói viselkedést. Ebből tudjuk meg, mely oldalak nem működnek jól. Ezek alapján senkit nem azonosítunk.